MYDATA My9 Theta error

Electronics Forum | Tue Nov 20 15:03:37 EST 2012 | jaimebc

Bruce, Since we had spares, I replaced the X wagon cables, XFMB cable, nothing. FFX Cable, nothing. Swapped mot cards, nothing. Vaccum seal, nothing.At this point I truly believe the problem is either on the theta encoder or the theta motor. Unfortu

MYdata 15E F-Mot error

Electronics Forum | Fri May 24 11:34:08 EDT 2019 | jstebbs89

Running a Mydata 15E and in the middle of a board the machine will freeze. Restart the machine and try to initiate the hardware, get an error message of F-MOT-MSETDYN X/163: Illegal value of DSP command arguement I've check all the connections on t

MY 9 error F-MOT-MSETDYN X/163

Electronics Forum | Thu Mar 23 13:36:30 EDT 2023 | tomdegas

Running a Mydata MY 9 and trying to Restart the machine and try to initiate the hardware, get an error message of F-MOT-MSETDYN X/163: Illegal value of DSP command argument. It seems to be related to the x drive. I've check all the connections on

MYDATA MY15E F-MOT-MOVE X/250 problem

Electronics Forum | Fri Nov 22 10:24:28 EST 2019 | rgduval

When you swapped the MOT card, did the proble move to another axis? I'm guessing no, but, wanted to clarify. If the problem did not move, you either have an x-motor problem, x-motor counter problem, or x-transducer problem as noted. Or, a cable pr

MYDATA HYDRA Z/156 error on Hardware Intialization.

Electronics Forum | Fri Mar 06 19:32:09 EST 2020 | SMTA-Alex

The fact, that your Hydra head goes up and then starts moving slowly, means that it didn't find the limit. Since there are no mechanical obstructions and you swapped all the boards, the things to look at are cabling. Double check the ribbon cables fo

Mydaya Camera issue

Electronics Forum | Sun Nov 27 11:19:55 EST 2005 | cyber_wolf

Dude, Scope the big ribbon cables on either side of the X-axis for cracks. They usually break where the clamp holds them on the X wagon. Also, all of your X camera stuff goes through the XWB board.Try swapping it if you have another. I am not sure

MYDATA HYDRA Z/156 error on Hardware Intialization.

Electronics Forum | Mon Apr 06 17:08:30 EDT 2020 | tima

Try swapping XWB board that is on top of X-Wagon. Have you try that? All signals go thru there. Another thing can be those 2 ribbon cables that are behind of X-Wagon. How long ago did you change them? What I would do is to move X to different positio

Mydata A12 tool tip damage

Electronics Forum | Wed Jul 18 07:48:12 EDT 2007 | cyber_wolf

Bad small X motor most likely. Other possibilities: Bad cables Bad Card

Mydata TP9-2 Help

Electronics Forum | Mon Aug 06 18:58:12 EDT 2007 | edruppert

This message indicates that the Peak to Peak voltage for the x axis motor encoder is too low. Possible cable/encoder or MOT1 board problem. Machine will either exhibit this during intialization or while running. Diagnostics in service routine may he

Mydata TP11-UFP won't initialize

Electronics Forum | Thu Jan 06 13:56:46 EST 2011 | ev

Thanks for this detail. The X wagon responds as per the instructions here so I'll give the cables a good inspection.


mydata my12 x cable searches for Companies, Equipment, Machines, Suppliers & Information

2024 Eptac IPC Certification Training Schedule

Stencil Printing 101 Training Course
Win Source Online Electronic parts

Software programs for SMT placement and AOI Inspection machines from CAD or Gerber.
PCB Handling with CE

Training online, at your facility, or at one of our worldwide training centers"