Full Site - : mydata my12 x cable (Page 5 of 12)

transducers out of sync error, Mydata TP-11

Electronics Forum | Tue Feb 28 08:19:03 EST 2012 | cyber_wolf

Replace both of the big X-wagon ribbon cables to start with. You always have to rule those out before looking at anything else.

Mydata TP-11 Small X not working

Electronics Forum | Thu Mar 26 08:51:40 EDT 2009 | avalancher

Hi Sr. First suggestion is to call Mydata's phone support. With that said... Here is some ideas of what you could check: 1. Do you have power at the XWB board connector going to the motor (xxwm connector)? 2. Do you have power coming through the bl

Need Help on MYDATA MY12 Initiate Hardware Error

Electronics Forum | Thu Jul 24 11:02:29 EDT 2008 | markhoch

Try swapping the MOT card. Just be sure not to swap with the X-Axis card.

MY12 F-MOT-MSETDYN x/12: Position Counter Dead

Electronics Forum | Fri Sep 05 09:42:41 EDT 2014 | cflames17

If you call service they can also walk you through the motor test. Ask for Glen. Al no longer works for MYDATA.

Mydata TP11-UFP F-MOT1-38/245

Electronics Forum | Mon Oct 25 11:20:52 EDT 2021 | bk

The 245 error is with your x belt motor not the x wagon motor. double check all the fuses on the back of the machine where your power comes in there should be 3 of them. if you haven't changed your blue cables in a while I would change those out. you

MY12 F-MOT-MSETDYN x/12: Position Counter Dead

Electronics Forum | Fri Sep 05 09:22:53 EDT 2014 | rgduval

Hi, Rebecca, Hmm...two x motors? I'm a couple of years removed from MyData's, but, I don't remember two x-motors. Might be something in the My12's that I didn't see in my older My9 (and certainly not in my TP9). As to the small board...unfortun

MY12 F-MOT-MSETDYN x/12: Position Counter Dead

Electronics Forum | Wed Sep 03 15:18:12 EDT 2014 | chemers

I am looking for some help for where to look to fix this MY12 problem. We started the machine after the weekend and this error code comes up during initialization. F-MOT-MSETDYN X/12: Position counter dead MyData tells us our only option is to have

Mydata (MY12) error-Frame Grab and Light Curtain

Electronics Forum | Wed Sep 23 08:19:52 EDT 2009 | rgduval

Check to see if there's a loose cable, or something, that's randomly setting off the light curtain. We occasionally have that problem with some of our flex or 12/16 mags in our TP9, where the tape take up clip is loose (nothing in that feeder) and i

MY12 HYDRA issu

Electronics Forum | Mon Dec 26 18:02:37 EST 2022 | rgduval

So, your Hydra Z message timed out... A couple of potential causes: 1. Hydra MOT card failure 2. Hydra z-motor failure 3. Hydra z-motor encoder failure 4. Hydra z-lock failure 5. Disconnected cable 6. X-wagon cable Start by booting into service mod

Mydata - Level too high in pick

Electronics Forum | Thu Sep 19 10:27:10 EDT 2013 | rgduval

I believe there is a force calibration menu option in the maintenance menu. From the main screen, choose exit to maintenance to get into the maintenance menus. If you're still having force issues afterwards, you'll want to start hunting for broke