Mydata TP9-2U error ?

Electronics Forum | Thu Aug 22 11:30:47 EDT 2019 | rgduval

It's a motor controller card error. I'm not completely sure, but, it seems like something in the x. Swap MOT1 with MOT2 or 3, and see if the error moves. If it does, you have a bad MOT card. If it doesn't, you have something going on with a motor

Mydata TP-11 Small X not working

Electronics Forum | Mon Apr 20 08:32:28 EDT 2009 | cyber_wolf

I actually did replace the cable from the comp box to the X-boards. The original small x-motor was indeed bad. I verified this by taking it to my working machine and trying to pulse it when it was in my hand. (the mot boards were loaded). Then I to

Mydata TP11 1995

Electronics Forum | Tue Apr 05 11:03:13 EDT 2005 | cyber_wolf

There are several things that can cause these errors. It sounds as if you have 2 problems. A (Z) problem and a theta problem. 1. Check that the Z-locks are functioning properly in the service program. Make sure that when they are un-locked they don'

Mydata TP-11 Small X not working

Electronics Forum | Thu Mar 26 11:29:31 EDT 2009 | cyber_wolf

I talked to Mydata service (briefly) 3 times. Halfway through the 3rd call it was suggested to me that we set up a service call. Times being what they are, we are not willing to go that route yet. Thankfully we are not in dire need of this machine ri

Mydata TP-11 Small X not working

Electronics Forum | Wed Mar 25 14:55:17 EDT 2009 | cyber_wolf

The small x motor quit working.It seems that there is no voltage going to the motor. Here is what I have done so far: *Verified that the motor is good. *Check pico fuses on the backplane *Verify voltages on backplane and on big booster. *Swap mot ca

MYDATA TP9-4 MI board

Electronics Forum | Tue Jun 01 08:42:08 EDT 2010 | rgduval

I'm randomly having some motor move errors, as well. If you swap your MOT board, and the problem continues, you're down to a couple of problems. Could be that the motor is getting ready to die on you. Could be an encoder problem. Or, could be som

MYDATA vs ASSEMBLEON

Electronics Forum | Wed Apr 27 08:50:34 EDT 2005 | joseluis_amper

Hi. I try to decide in this moment what machine bye, Mydata o Assembleon (My12 or Emerald X(i)). In this moment we need to know the technical problems that has one or the other. Do you think that is neccessary have a mantenance contract or not?. Our

Mydata (MY12) error-Frame Grab and Light Curtain

Electronics Forum | Tue Sep 22 16:39:10 EDT 2009 | rmitchell

Hi, We are getting a E-Hydra-1 Frame grabbing failed on caps and resistors and also a Light Curtain trigger X wagon. I spoke with mydata and they indicated the light curtain might be getting set off and causing the frame grabbing failure. I cleane

Mydata M12 issue

Electronics Forum | Mon Oct 05 10:29:38 EDT 2009 | cyber_wolf

I ended up finding that there were broken chords on the X-belt. I replaced it and all is good. Rob, Mydata is right. You can indeed end up spending lots of time and money trying to chase a transducer error. Things I would look at: 1. Lubing the X b

Tray table set up on Tray Wagon Mydata MY12

Electronics Forum | Sun Apr 07 00:45:21 EDT 2019 | d_nguyen2018

Hi, Can you show me how to set up tray table? I have 1 x 10 pockets tape with 10 PQFPs. I went into Magazines then selected Tray Wagon. I did first and last part on the 1 x 10 tape pockets but it did not work. I was told that I must set up the tray


mydata my12 x cable searches for Companies, Equipment, Machines, Suppliers & Information

Hot selling SMT spare parts and professional SMT machine solutions

Software programs for SMT placement and AOI Inspection machines from CAD or Gerber.
Blackfox IPC Training & Certification

World's Best Reflow Oven Customizable for Unique Applications
SMT feeders

High Precision Fluid Dispensers