MYDATA TP9-4 MI board

Electronics Forum | Tue Jun 01 08:42:08 EDT 2010 | rgduval

I'm randomly having some motor move errors, as well. If you swap your MOT board, and the problem continues, you're down to a couple of problems. Could be that the motor is getting ready to die on you. Could be an encoder problem. Or, could be som

MYDATA vs ASSEMBLEON

Electronics Forum | Wed Apr 27 08:50:34 EDT 2005 | joseluis_amper

Hi. I try to decide in this moment what machine bye, Mydata o Assembleon (My12 or Emerald X(i)). In this moment we need to know the technical problems that has one or the other. Do you think that is neccessary have a mantenance contract or not?. Our

Mydata (MY12) error-Frame Grab and Light Curtain

Electronics Forum | Tue Sep 22 16:39:10 EDT 2009 | rmitchell

Hi, We are getting a E-Hydra-1 Frame grabbing failed on caps and resistors and also a Light Curtain trigger X wagon. I spoke with mydata and they indicated the light curtain might be getting set off and causing the frame grabbing failure. I cleane

Mydata M12 issue

Electronics Forum | Mon Oct 05 10:29:38 EDT 2009 | cyber_wolf

I ended up finding that there were broken chords on the X-belt. I replaced it and all is good. Rob, Mydata is right. You can indeed end up spending lots of time and money trying to chase a transducer error. Things I would look at: 1. Lubing the X b

Tray table set up on Tray Wagon Mydata MY12

Electronics Forum | Sun Apr 07 00:45:21 EDT 2019 | d_nguyen2018

Hi, Can you show me how to set up tray table? I have 1 x 10 pockets tape with 10 PQFPs. I went into Magazines then selected Tray Wagon. I did first and last part on the 1 x 10 tape pockets but it did not work. I was told that I must set up the tray

MY12 F-MOT-MSETDYN x/12: Position Counter Dead

Electronics Forum | Thu Sep 04 16:36:29 EDT 2014 | chemers

Thanks for the response, Rob. I tried the MOT cards and the problem did not move. I swapped the MOTY with the MOTX, but the MOTX had a small board attached to it that I moved to the MOTY that I tried. Do you know if there is a way to test that small

MY12 F-MOT-MSETDYN x/12: Position Counter Dead

Electronics Forum | Fri Sep 05 09:33:32 EDT 2014 | cflames17

It could very well be the Safety Relay located inside the ELMO PSU (Bottom left in computer cabinet). I just had the same problems on 2 MY9's within 2 months apart. the Part cost around $700.00 from Mydata (Now Mycronic). These fail commonly with old

Im trying to install a tool on a MY15 and I am getting errors

Electronics Forum | Fri Aug 06 14:01:53 EDT 2021 | tomdegas

Unfortunately all my tools are spring loaded. Yes I do know the tool install utility. I have been running and maintaining the 3 MyData machines for over 20 years and I never saw an error like this. I grease our tools once a month so I know that is

MYDATA My9 Theta error

Electronics Forum | Tue Nov 13 12:02:54 EST 2012 | jaimebc

I'll try swaping cards and see if the problem follows the card. So far, my guess would be the motor going bad. I did change the brushes, X wagon cables and every cable that goes to the midas unit. But that didn't fix it. The problem is that to replac

Mydata TP-11 Small X not working

Electronics Forum | Wed Apr 15 12:57:37 EDT 2009 | bk

I'm not sure if you fixed your problem yet or not but i'll give you some insight on your problem. The x wagon motor doesn't move cause of the voltage it actually moves when there's current applied to it. The voltage dictates the direction the motor m


mydata my12 x cable searches for Companies, Equipment, Machines, Suppliers & Information

SMT feeders

Software programs for SMT placement and AOI Inspection machines from CAD or Gerber.
SMT feeders

Have you found a solution to REDUCE DISPENSE REWORK? Your answer is here.
Global manufacturing solutions provider

Component Placement 101 Training Course
Professional technical team,good service, ready to ship- Various brands pick and place machine!

Private label coffee for your company - your logo & message on each bag!