Electronics Forum | Wed Mar 23 23:00:17 EST 2005 | pmd
Problem solved. Thru the help of MyData support we have determined that older MyDatas have a software issue with the servo drivers. A newer rev of driver will fix this problem.
Electronics Forum | Thu Mar 10 23:23:56 EST 2005 | pmd
We have a MyData TP-9-2 with a in line Y wagon. It is a long screw and the vintage is 1994. The Y wagon vibrates at about 24 micrometers at about 25 hertz. Burnin reviels zero encoder pulse errors. Hystersis test indicates a Y axis Y wise varance of
Electronics Forum | Wed Mar 16 17:43:33 EST 2005 | pmd
We grease acording to PM schedule. The cable is very old about 5 years. We run 2 shifts. The transducer program and burnin test show the varance that we are seeing phisically so I can rule out the transducer. The motor may be the cause as it is of 19
Electronics Forum | Fri Jan 10 11:32:52 EST 2014 | rgduval
Hi, Hans, I would have suggested swapping the MOT card out to see if that fixes the issue (or, changing the MOT card with another one to isolate the card), but, it sounds like you've already done that. I'm surprised that MyData would point you towa
Electronics Forum | Fri Jan 10 03:33:42 EST 2014 | hans88
hello people, we have a my12 wich has a problem it gives the following error during hardware initialization: F-MOT-MSETDYN Y/1236 :Motor amplifier channel a error. after this error it says hardware initialization failed. this prevents us of using
Electronics Forum | Sat Jan 29 04:59:02 EST 2005 | Grant
Hi, MYDATA's are ok for lower volume, and they are very flexible. If you only have 1 or 2 trays of components and are on a tight budget, then you can even place the trays on the Y wagon behind the PCB so you can get away without the tray wagon. Al
Electronics Forum | Tue Jul 14 13:20:13 EDT 2020 | tomdegas
I have a MY12 running TPS 2.8.1 and I need to know how to calibrate the X wagon Visin system. The machine is off in the Y direction after I removed and replaced the camera.
Electronics Forum | Thu Jun 14 00:10:18 EDT 2012 | tech1
Most of it depends upon the type of Y wagon you have. if they are internal conveyors you need to remove the covers from the operator side. There are 3 screws holding the Y wagon down, 2 of them are hex screws and the one in front is an allen head. W
Electronics Forum | Mon Jun 11 15:43:38 EDT 2012 | williamaxler
We are going to be moving some equipment around and our MY15 and TP11 will not fit through the door unless we take of the Y wagon. Does anyone know how to do this? If so could you please share with me.
Electronics Forum | Thu Oct 15 10:21:30 EDT 2015 | azdback
troubleshooting a table lift error on MY12. Error code: F-MOT_Releaseboard conveyor lift/1304. Basically, the table got stuck on the up position. Also bench tested both lift motors and they are ok.Rotated the lift motors manually to test the encoder