MYDATA MY15E F-MOT-MOVE X/250 problem

Electronics Forum | Fri Nov 22 00:09:29 EST 2019 | mk15

I am looking for some help for where to look to fix this MY15E problem. 1. after hardware initiation appear - F-MOT-MOVE X/250: Motor speed out of control (photo1). 2. in service mode when x motor initiate appear - F-MOT-MSETDYN X/12: No axis movemen

MYDATA MY15E F-MOT-SETDYN Z/3: Upper end point outside limit

Electronics Forum | Fri Oct 12 11:16:46 EDT 2018 | tech1

Sounds like one of the Z stops is not functioning or needs to be adjusted.

MYDATA MY15E F-MOT-MOVE X/250 problem

Electronics Forum | Mon Nov 25 02:15:07 EST 2019 | mk15

it is possible to test x belt motor and x wagon motor.

Juki vs Mydata... again...

Electronics Forum | Tue May 02 15:33:23 EDT 2006 | mdm4ua

I have five Mydata machines. The 21000 number is pie in the sky. Our new My12E (2 months old) won't get close to that. Having said that, I am very happy with 0201 production with the Hydra/line scan/Linear Agilis combination. Mike

MYDATA MY15E F-MOT-SETDYN Z/3: Upper end point outside limit

Electronics Forum | Tue Oct 30 12:47:17 EDT 2018 | padawanlinuxero

hello try to calibrate the Z axis, check the cable must be damage, check if the transducer is loose, just some options from the top of my head, have you try getting into service and make it work there? if not try that too.

MYDATA MY15E:F-MOT-MSETDYN conveyor transport/1250: amplifier DC-link too high

Electronics Forum | Thu Jul 18 00:08:31 EDT 2019 | mk15

hank you for the tips. MOT boards have already changed. The sensor on the conveyor responds. In service mode, the WIDTH MOTOR - OK, HOLD MOTOR - OK, SET CONVEYOR - OK, only error TRANSPORT - F-MOT-MSETDYN conveyor transport / 1250: amplifier DC-link

Mydata

Electronics Forum | Wed Feb 25 15:16:56 EST 2015 | dyoungquist

We have MY12 and MY15E machines. I am going to assume what we are seeing also applies to the MY100 series machines as well. Do you have the electrical verifier option that works with the midas head and centering jaws to check component values of

MYDATA MY15E:F-MOT-MSETDYN conveyor transport/1250: amplifier DC-link too high

Electronics Forum | Wed Jul 17 17:56:38 EDT 2019 | rgduval

Check the MOT board. You can usually swap out the individual MOT boards, and see if the problem moves. If it does, you can isolate which board has gone bad. You can also check the encoder on the conveyor, to make sure that is still working correct

MYDATA MY15E F-MOT-MOVE X/250 problem

Electronics Forum | Mon Nov 25 10:57:31 EST 2019 | rgduval

You should be able to see the counts in the service screen for the motors while testing them...that's usually the easiest way to see if they're functioning...at least the encoders. In some of the older systems, the drive motors were all the same, an

Samsung SM320 vs Mydata MY12E

Electronics Forum | Wed Mar 21 10:29:50 EDT 2007 | ccross

I am currently looking at new pick and place equipment and have come down to these two machines. I am interested on hearing from users of both, the pros and cons of their choice. I am a low volume high mix OEM upgrading from Quad QSX-1 and am interes