Full Site - : mydata my500 belt (Page 10 of 26)

Mydata M12 issue

Electronics Forum | Mon Oct 05 10:29:38 EDT 2009 | cyber_wolf

I ended up finding that there were broken chords on the X-belt. I replaced it and all is good. Rob, Mydata is right. You can indeed end up spending lots of time and money trying to chase a transducer error. Things I would look at: 1. Lubing the X b

TM12 Feeder problem for MYDATA TP9-UPF

Electronics Forum | Fri Mar 27 09:37:15 EDT 2009 | cyber_wolf

There are pem nuts on the back side of the teddy bear face. One of them probably fell off and either shorted your main board or it is lodged in the belt and pulley that drives the advancing wheels. Take the front part of the feeder off that has the t

Mydata TP11-UFP won't initialize

Electronics Forum | Tue Jan 04 13:00:07 EST 2011 | bk

The only x fan i can think of would be the x belt motor fan which is on the back of the black box sticking out of the back of the machine. If it's a heat issue then first thing to do is replace the 2 filters behind the 2 vented covers located on the

Mydata MY12 Hydra Theta error

Electronics Forum | Mon Nov 21 21:46:49 EST 2011 | supse

Thanks Phil But the belt and spring has been changed recently. Unfortunatly we couldn't wait any longer for a solution, so we had to go for a change of the hydra-unit. This seems to have solved the matter, but I had hoped for a less expensive solutio

Mydata (TP9-2U) problem

Electronics Forum | Tue May 07 16:36:04 EDT 2013 | shankar2013

Actually thinking of LX14, but for now I need to solve this problem. We have replaced centering jaws, the steel belts for regular maintenance. I don't think there is anything binding. The strangest thing is every time it shuts down it is right at the

Issue with MYDATA MY19 "Transducers do not agree"

Electronics Forum | Wed Feb 12 15:11:29 EST 2020 | alvarez94

I was consulting the manual of the machine and to measure the tension of the x belt I need a frequency counter and two prisms but I don't have these tools, is there any other way to measure the tension?

Mydata TP11-UFP F-MOT1-38/245

Electronics Forum | Mon Oct 25 11:20:52 EDT 2021 | bk

The 245 error is with your x belt motor not the x wagon motor. double check all the fuses on the back of the machine where your power comes in there should be 3 of them. if you haven't changed your blue cables in a while I would change those out. you

Mydata My9 X MOT motor timeout

Electronics Forum | Tue Jun 14 15:59:25 EDT 2022 | mikevb

Thanks! I just needed a response like that. I will do all that, and if it's still an issue, I'll change the x wagon encoder right? There are three encoders on the x wagon though? The white one on the x carriage, the white one on the x belt drive mo

MY12 F-MOT-MSETDYN x/12: Position Counter Dead

Electronics Forum | Thu Sep 04 16:36:29 EDT 2014 | chemers

Thanks for the response, Rob. I tried the MOT cards and the problem did not move. I swapped the MOTY with the MOTX, but the MOTX had a small board attached to it that I moved to the MOTY that I tried. Do you know if there is a way to test that small

MY 19 Issues?

Electronics Forum | Mon Dec 07 09:43:09 EST 2009 | kpm135

Just to throw my two cents in the MY19 could be slower than the other my machines due to the greater distance the head has to travel to pick up and place the components.The longer distance could also account for extra wear and tear on the motors and


mydata my500 belt searches for Companies, Equipment, Machines, Suppliers & Information

2024 Eptac IPC Certification Training Schedule

World's Best Reflow Oven Customizable for Unique Applications
Selective Soldering Nozzles

Nozzles, Feeders, Spare Parts - Siemens, Fuji, Juki, Yamaha, etc...
Electronics Equipment Consignment

High Throughput Reflow Oven
Assembly Automation Technology

"回流焊炉"