Electronics Forum | Thu Mar 10 15:13:31 EST 2005 | pmd
I agree with SirTec. Conflicts with other magazines slotted into machine often cause un reckognized magazine errors elseware. You can also try to re seat the first pair of MOT driver cards in computer this is whare mag data is stored. Also a loose ca
Electronics Forum | Wed May 11 20:36:32 EDT 2022 | stephendo
When was the last time you changed the flat ribbon cable on the top? Anytime I had trouble with a mydata that was the first thing they asked.
Electronics Forum | Wed Apr 06 07:59:17 EDT 2005 | cyber_wolf
Did you check the ribbon cables on either side of the X axis for cracks ?
Electronics Forum | Mon May 09 19:00:47 EDT 2022 | SMTA-64387687
Z-force sensor is a tool travel indicator. It has nothing to do with Z travel. Does the Midas head move at all, during initiation? It sounds to me like a Z motor/encoder problem. Is the Midas head ribbon cable plugged in?
Electronics Forum | Thu Mar 23 13:36:30 EDT 2023 | tomdegas
Running a Mydata MY 9 and trying to Restart the machine and try to initiate the hardware, get an error message of F-MOT-MSETDYN X/163: Illegal value of DSP command argument. It seems to be related to the x drive. I've check all the connections on
Electronics Forum | Sat Mar 25 12:51:14 EDT 2023 | rgduval
Swap mot cards and see if the error moves. Of it does, your issue is the mot card, if it doesn't, your issue is one of the above. Try calibrating in the service menu. Check your friction readings. Check the x-encoder (attached to the motor).
Electronics Forum | Tue Nov 20 15:03:37 EST 2012 | jaimebc
Bruce, Since we had spares, I replaced the X wagon cables, XFMB cable, nothing. FFX Cable, nothing. Swapped mot cards, nothing. Vaccum seal, nothing.At this point I truly believe the problem is either on the theta encoder or the theta motor. Unfortu
Electronics Forum | Tue Feb 28 08:19:03 EST 2012 | cyber_wolf
Replace both of the big X-wagon ribbon cables to start with. You always have to rule those out before looking at anything else.
Electronics Forum | Fri Mar 06 19:32:09 EST 2020 | SMTA-Alex
The fact, that your Hydra head goes up and then starts moving slowly, means that it didn't find the limit. Since there are no mechanical obstructions and you swapped all the boards, the things to look at are cabling. Double check the ribbon cables fo
Electronics Forum | Sun Nov 27 11:19:55 EST 2005 | cyber_wolf
Dude, Scope the big ribbon cables on either side of the X-axis for cracks. They usually break where the clamp holds them on the X wagon. Also, all of your X camera stuff goes through the XWB board.Try swapping it if you have another. I am not sure