Mydata TP-11 Small X not working

Electronics Forum | Thu Mar 26 08:51:40 EDT 2009 | avalancher

Hi Sr. First suggestion is to call Mydata's phone support. With that said... Here is some ideas of what you could check: 1. Do you have power at the XWB board connector going to the motor (xxwm connector)? 2. Do you have power coming through the bl

Mydata - Level too high in pick

Electronics Forum | Thu Sep 19 10:27:10 EDT 2013 | rgduval

I believe there is a force calibration menu option in the maintenance menu. From the main screen, choose exit to maintenance to get into the maintenance menus. If you're still having force issues afterwards, you'll want to start hunting for broke

MYDATA MY15E F-MOT-MOVE X/250 problem

Electronics Forum | Fri Nov 22 10:24:28 EST 2019 | rgduval

When you swapped the MOT card, did the proble move to another axis? I'm guessing no, but, wanted to clarify. If the problem did not move, you either have an x-motor problem, x-motor counter problem, or x-transducer problem as noted. Or, a cable pr

Mydata TP11 1995

Electronics Forum | Tue Apr 05 11:03:13 EDT 2005 | cyber_wolf

There are several things that can cause these errors. It sounds as if you have 2 problems. A (Z) problem and a theta problem. 1. Check that the Z-locks are functioning properly in the service program. Make sure that when they are un-locked they don'

Mydata TP-11 Small X not working

Electronics Forum | Wed Mar 25 14:55:17 EDT 2009 | cyber_wolf

The small x motor quit working.It seems that there is no voltage going to the motor. Here is what I have done so far: *Verified that the motor is good. *Check pico fuses on the backplane *Verify voltages on backplane and on big booster. *Swap mot ca

MYDATA TP9-4 MI board

Electronics Forum | Tue Jun 01 08:42:08 EDT 2010 | rgduval

I'm randomly having some motor move errors, as well. If you swap your MOT board, and the problem continues, you're down to a couple of problems. Could be that the motor is getting ready to die on you. Could be an encoder problem. Or, could be som

Im trying to install a tool on a MY15 and I am getting errors

Electronics Forum | Fri Aug 06 14:01:53 EDT 2021 | tomdegas

Unfortunately all my tools are spring loaded. Yes I do know the tool install utility. I have been running and maintaining the 3 MyData machines for over 20 years and I never saw an error like this. I grease our tools once a month so I know that is

Mydata TP-11 Small X not working

Electronics Forum | Thu Mar 26 11:29:31 EDT 2009 | cyber_wolf

I talked to Mydata service (briefly) 3 times. Halfway through the 3rd call it was suggested to me that we set up a service call. Times being what they are, we are not willing to go that route yet. Thankfully we are not in dire need of this machine ri

Mydata M12 issue

Electronics Forum | Mon Oct 05 10:29:38 EDT 2009 | cyber_wolf

I ended up finding that there were broken chords on the X-belt. I replaced it and all is good. Rob, Mydata is right. You can indeed end up spending lots of time and money trying to chase a transducer error. Things I would look at: 1. Lubing the X b

MYDATA My9 Theta error

Electronics Forum | Tue Nov 13 12:02:54 EST 2012 | jaimebc

I'll try swaping cards and see if the problem follows the card. So far, my guess would be the motor going bad. I did change the brushes, X wagon cables and every cable that goes to the midas unit. But that didn't fix it. The problem is that to replac


mydata my9 x ribbon cable searches for Companies, Equipment, Machines, Suppliers & Information

PCB Handling Machine with CE

Training online, at your facility, or at one of our worldwide training centers"
SMT feeders

High Precision Fluid Dispensers
Global manufacturing solutions provider

Wave Soldering 101 Training Course


SMT & PCB Equipment - MPM, DEK, Heller, Europlacer and more...