Full Site - : mydata my9 x ribbon cable (Page 1 of 3)

Mydata TP11 1995

Electronics Forum | Wed Apr 06 07:59:17 EDT 2005 | cyber_wolf

Did you check the ribbon cables on either side of the X axis for cracks ?

MyData My9 "no z indicator value at all"

Electronics Forum | Mon May 09 19:00:47 EDT 2022 | SMTA-64387687

Z-force sensor is a tool travel indicator. It has nothing to do with Z travel. Does the Midas head move at all, during initiation? It sounds to me like a Z motor/encoder problem. Is the Midas head ribbon cable plugged in?

MY 9 error F-MOT-MSETDYN X/163

Electronics Forum | Thu Mar 23 13:36:30 EDT 2023 | tomdegas

Running a Mydata MY 9 and trying to Restart the machine and try to initiate the hardware, get an error message of F-MOT-MSETDYN X/163: Illegal value of DSP command argument. It seems to be related to the x drive. I've check all the connections on

MY 9 error F-MOT-MSETDYN X/163

Electronics Forum | Sat Mar 25 12:51:14 EDT 2023 | rgduval

Swap mot cards and see if the error moves. Of it does, your issue is the mot card, if it doesn't, your issue is one of the above. Try calibrating in the service menu. Check your friction readings. Check the x-encoder (attached to the motor).

MYDATA My9 Theta error

Electronics Forum | Tue Nov 20 15:03:37 EST 2012 | jaimebc

Bruce, Since we had spares, I replaced the X wagon cables, XFMB cable, nothing. FFX Cable, nothing. Swapped mot cards, nothing. Vaccum seal, nothing.At this point I truly believe the problem is either on the theta encoder or the theta motor. Unfortu

transducers out of sync error, Mydata TP-11

Electronics Forum | Tue Feb 28 08:19:03 EST 2012 | cyber_wolf

Replace both of the big X-wagon ribbon cables to start with. You always have to rule those out before looking at anything else.

MYDATA HYDRA Z/156 error on Hardware Intialization.

Electronics Forum | Fri Mar 06 19:32:09 EST 2020 | SMTA-Alex

The fact, that your Hydra head goes up and then starts moving slowly, means that it didn't find the limit. Since there are no mechanical obstructions and you swapped all the boards, the things to look at are cabling. Double check the ribbon cables fo

Mydaya Camera issue

Electronics Forum | Sun Nov 27 11:19:55 EST 2005 | cyber_wolf

Dude, Scope the big ribbon cables on either side of the X-axis for cracks. They usually break where the clamp holds them on the X wagon. Also, all of your X camera stuff goes through the XWB board.Try swapping it if you have another. I am not sure

MYDATA HYDRA Z/156 error on Hardware Intialization.

Electronics Forum | Mon Apr 06 17:08:30 EDT 2020 | tima

Try swapping XWB board that is on top of X-Wagon. Have you try that? All signals go thru there. Another thing can be those 2 ribbon cables that are behind of X-Wagon. How long ago did you change them? What I would do is to move X to different positio

Mycronic vs. Juki: Your Opinions?

Electronics Forum | Fri Mar 24 16:45:03 EDT 2023 | tey422

I believe I was working with the early MY12 model too. Yes, the X-wagon blue ribbon cable were showing wear and tear very fast. Another frequent break downs were the center-jaw, ribbon broke. Most of the Mydata repairs can be done inhouse with spar


mydata my9 x ribbon cable searches for Companies, Equipment, Machines, Suppliers & Information

2024 Eptac IPC Certification Training Schedule

Software for SMT placement & AOI - Free Download.
convection smt reflow ovens

Best Reflow Oven
SMTAI 2024 - SMTA International

World's Best Reflow Oven Customizable for Unique Applications