Used SMT Equipment | Pick and Place/Feeders
Vintage: 2005 Software: TPSys 2.5.4d for Linux Details: • Electrical two-pole test • Optical centering • Conveyor • Shared databases • Dual Vision Camera • Linescan Camera • T3 Linear Drive Y-Wagon w/ YBOX 2 Upgrade • Midas Head •
Used SMT Equipment | Pick and Place/Feeders
Make: Mydata Model: My100 SXE Vintage: 2012 Software: TPSys 2.9.25c Details: • Electrical two-pole test • Electrical transistor test • Optical Centering • Barcode Reader • Conveyor • Shared da
Parts & Supplies | Pick and Place/Feeders
X-wagon motor for Mycronic-Mydata machines MY9-19, TP. Used, good condition. Available in stock for quick shipping. View this part on LandrySMT web site: https://www.landrysmt.fr/produit/mycronic-x-wagon-motor-l-049-0118/
Used SMT Equipment | Pick and Place/Feeders
MyData (MyCronic) My9 Serial No: 5576 Manufactured: 10/27/2006 Up Time: 166 days Assembly Time: 35 days Software Options: Electrical testing Optical centering Conveyors Shared database Hydra 14k High speed Z Autoteach Hydra large compo
Used SMT Equipment | Pick and Place/Feeders
HUGE 36" x 28" pcb capability. Fast, flexible, and capable. The standard in ease of use. Configuration: ML6 (big board) Y-wagon Tray wagon magazine Tpsys version 2.9.13e Active options Electrical two-pole test & Electrical tran
Industry News | 2005-02-17 09:43:45.0
STOCKHOLM, Sweden, Feb 14, 2005
Electronics Forum | Sat Jan 29 04:59:02 EST 2005 | Grant
Hi, MYDATA's are ok for lower volume, and they are very flexible. If you only have 1 or 2 trays of components and are on a tight budget, then you can even place the trays on the Y wagon behind the PCB so you can get away without the tray wagon. Al
Electronics Forum | Tue Nov 20 15:03:37 EST 2012 | jaimebc
Bruce, Since we had spares, I replaced the X wagon cables, XFMB cable, nothing. FFX Cable, nothing. Swapped mot cards, nothing. Vaccum seal, nothing.At this point I truly believe the problem is either on the theta encoder or the theta motor. Unfortu
Electronics Forum | Tue Nov 13 12:02:54 EST 2012 | jaimebc
I'll try swaping cards and see if the problem follows the card. So far, my guess would be the motor going bad. I did change the brushes, X wagon cables and every cable that goes to the midas unit. But that didn't fix it. The problem is that to replac
Electronics Forum | Thu Mar 23 13:36:30 EDT 2023 | tomdegas
Running a Mydata MY 9 and trying to Restart the machine and try to initiate the hardware, get an error message of F-MOT-MSETDYN X/163: Illegal value of DSP command argument. It seems to be related to the x drive. I've check all the connections on