Full Site - : mydata ribbon (Page 3 of 5)

Mydata TP-11 Small X not working

Electronics Forum | Wed Mar 25 14:55:17 EDT 2009 | cyber_wolf

The small x motor quit working.It seems that there is no voltage going to the motor. Here is what I have done so far: *Verified that the motor is good. *Check pico fuses on the backplane *Verify voltages on backplane and on big booster. *Swap mot ca

MYDATA TP9-4 MI board

Electronics Forum | Tue Jun 01 08:42:08 EDT 2010 | rgduval

I'm randomly having some motor move errors, as well. If you swap your MOT board, and the problem continues, you're down to a couple of problems. Could be that the motor is getting ready to die on you. Could be an encoder problem. Or, could be som

Mydata (TP9-2U) problem

Electronics Forum | Tue May 07 13:51:51 EDT 2013 | shankar2013

acceleration is set to lowest. Ribbon cables were replaced, theta motor replaced. I also see a message pop up just after F-MOT1-26/156:MOVFI: MOTOR TIMEOUT / F-AXIS-182:C-AXIS NOT properly out when expected / 25v reads 3V. Now all these messages

MYDATA HYDRA Z/156 error on Hardware Intialization.

Electronics Forum | Wed Mar 04 13:45:01 EST 2020 | tomdegas

I appreciate the help. The Hydra travel is fine and goes down and back up with no trouble. I swapped the Z Mot board with the Y Mot board with no change. The long ribbon cables were changed about a month ago but I will inspect them again to be sure.

Im trying to install a tool on a MY15 and I am getting errors

Electronics Forum | Fri Aug 06 14:01:53 EDT 2021 | tomdegas

Unfortunately all my tools are spring loaded. Yes I do know the tool install utility. I have been running and maintaining the 3 MyData machines for over 20 years and I never saw an error like this. I grease our tools once a month so I know that is

MyData Y wagon shudder

Electronics Forum | Thu Mar 10 23:23:56 EST 2005 | pmd

We have a MyData TP-9-2 with a in line Y wagon. It is a long screw and the vintage is 1994. The Y wagon vibrates at about 24 micrometers at about 25 hertz. Burnin reviels zero encoder pulse errors. Hystersis test indicates a Y axis Y wise varance of

Mydata TP-11 Small X not working

Electronics Forum | Thu Mar 26 11:29:31 EDT 2009 | cyber_wolf

I talked to Mydata service (briefly) 3 times. Halfway through the 3rd call it was suggested to me that we set up a service call. Times being what they are, we are not willing to go that route yet. Thankfully we are not in dire need of this machine ri

Mydata M12 issue

Electronics Forum | Mon Oct 05 10:29:38 EDT 2009 | cyber_wolf

I ended up finding that there were broken chords on the X-belt. I replaced it and all is good. Rob, Mydata is right. You can indeed end up spending lots of time and money trying to chase a transducer error. Things I would look at: 1. Lubing the X b

Mydata M12 issue

Electronics Forum | Tue Oct 27 15:53:23 EDT 2009 | smtspecialist

Sr.Tech is absolutely right !!! This is where I had started, by changing all 4 brushes on the motor then I changed the connector since it was turning black (Mydata have a retrofit connector assy for that!, you can do your own also!) After trying thos

MyData tool damage

Electronics Forum | Wed Jan 05 10:55:12 EST 2005 | OverTheHill

WOW Sr.Tech, 40K worth of bent tools? I'm about ready to be sh*t canned because of 1K's worth. As for trimming the mags, the product is running fine (many boards) and then out of nowhere the tool bends, so I assume my PERFECT operators trimmed the ma


mydata ribbon searches for Companies, Equipment, Machines, Suppliers & Information

ISVI High Resolution Fast Speed Industrial Cameras

High Throughput Reflow Oven
2024 Eptac IPC Certification Training Schedule