Full Site - : mydata ribbon (Page 1 of 5)

Mydata - Level too high in pick

Electronics Forum | Mon Aug 27 08:37:13 EDT 2012 | rgduval

If you're still having this problem, talk to Al at MyData about replacing the ribbon cable that is wrapped inside the head, and connected to the two LED's. It's a bit of a pain to replace this cable, but, it did fix the problem for us. The other po

Mycronic vs. Juki: Your Opinions?

Electronics Forum | Fri Mar 24 16:45:03 EDT 2023 | tey422

I believe I was working with the early MY12 model too. Yes, the X-wagon blue ribbon cable were showing wear and tear very fast. Another frequent break downs were the center-jaw, ribbon broke. Most of the Mydata repairs can be done inhouse with spar

Mydata TP11 1995

Electronics Forum | Wed Apr 06 07:59:17 EDT 2005 | cyber_wolf

Did you check the ribbon cables on either side of the X axis for cracks ?

MyDATA 12e Machine blowing fuses when powered

Electronics Forum | Tue Jun 07 20:27:08 EDT 2022 | SMTA-64387687

The ribbon cables might be shorting. Have you replaced them?

MyData My9 "no z indicator value at all"

Electronics Forum | Wed May 11 20:36:32 EDT 2022 | stephendo

When was the last time you changed the flat ribbon cable on the top? Anytime I had trouble with a mydata that was the first thing they asked.

transducers out of sync error, Mydata TP-11

Electronics Forum | Tue Feb 28 08:19:03 EST 2012 | cyber_wolf

Replace both of the big X-wagon ribbon cables to start with. You always have to rule those out before looking at anything else.

Mydata (TP9-2U) problem

Electronics Forum | Tue May 07 13:41:36 EDT 2013 | cyber_wolf

MOVFI is a theta error there are about 10 things that can cause it. Start with making sure you do not have an acceleration set to lowest while the others are at high or highest in the package data. Next look at ribbon cables...

Mydata theta problem

Electronics Forum | Thu Sep 17 15:06:19 EDT 2015 | alexvolovich

Check the vacuum tube on the Zfi head. Make sure the ty-rap isn't interfering. Then check the ribbon cables.

Mydata theta problem

Electronics Forum | Fri Sep 18 10:58:04 EDT 2015 | adventurelights

Thanks, have checked the vacuum tube and ribbon cables. They seem to look ok. Theta motor seems to be woking. I'm leaning towards the theta encoder going wanky. Is that possible?

Issue with MYDATA MY19 "Transducers do not agree"

Electronics Forum | Wed Feb 12 15:15:10 EST 2020 | SMTA-Alex

Not really, just eyeball. Does it look too loose or feel too tight. Is it lubricated properly, is there enough grease on the sprockets? Also, check the ribbon cables. They might be damaged.


mydata ribbon searches for Companies, Equipment, Machines, Suppliers & Information

SMT spare parts - Qinyi Electronics

Reflow Soldering 101 Training Course
Global manufacturing solutions provider