Mydata M12 issue

Electronics Forum | Tue Oct 27 15:53:23 EDT 2009 | smtspecialist

Sr.Tech is absolutely right !!! This is where I had started, by changing all 4 brushes on the motor then I changed the connector since it was turning black (Mydata have a retrofit connector assy for that!, you can do your own also!) After trying thos

MyData tool damage

Electronics Forum | Wed Jan 05 10:55:12 EST 2005 | OverTheHill

WOW Sr.Tech, 40K worth of bent tools? I'm about ready to be sh*t canned because of 1K's worth. As for trimming the mags, the product is running fine (many boards) and then out of nowhere the tool bends, so I assume my PERFECT operators trimmed the ma

MY19 Feeder advance problem slot 2

Electronics Forum | Wed Jun 04 00:28:27 EDT 2008 | chrispy1963

There are a couple of things that you can do. First thing to do is take a flashlight and shine it in the card edge connector of slot 2 and see if a passive component or any other part worked its way into that slot. This will cause multiple leads in

Mydata TP-11 Small X not working

Electronics Forum | Wed Apr 15 12:57:37 EDT 2009 | bk

I'm not sure if you fixed your problem yet or not but i'll give you some insight on your problem. The x wagon motor doesn't move cause of the voltage it actually moves when there's current applied to it. The voltage dictates the direction the motor m

Mydata MY15 Y-Wagon

Electronics Forum | Thu Jun 14 00:10:18 EDT 2012 | tech1

Most of it depends upon the type of Y wagon you have. if they are internal conveyors you need to remove the covers from the operator side. There are 3 screws holding the Y wagon down, 2 of them are hex screws and the one in front is an allen head. W

MYDATA MY15E F-MOT-MOVE X/250 problem

Electronics Forum | Fri Nov 22 10:24:28 EST 2019 | rgduval

When you swapped the MOT card, did the proble move to another axis? I'm guessing no, but, wanted to clarify. If the problem did not move, you either have an x-motor problem, x-motor counter problem, or x-transducer problem as noted. Or, a cable pr

MYDATA HYDRA Z/156 error on Hardware Intialization.

Electronics Forum | Wed Mar 04 12:51:41 EST 2020 | bk

That error means your hydra z did not reach it's specified position. With the machine on you should be able to manually push the hydra down and let it come back up. Make sure it isn't being held up or hitting anything as goes down. Lots of times a pa

MyData tool damage

Electronics Forum | Wed Jan 05 09:24:53 EST 2005 | cyber_wolf

Well...here is what I can tell you: I have over $40K worth of bent A12,A13,A14 tools.Yes you heard me right $40K worth. (Since 1995) Mydata used to make a repair kit to fix them but decided to quit. They tell me the reason they quit making the kit i

MY12 F-MOT-MSETDYN x/12: Position Counter Dead

Electronics Forum | Thu Sep 04 09:40:14 EDT 2014 | rgduval

I'm surprised MyData is pushing the service call. They're usually pretty good at walking you through some troubleshooting steps before going straight to the service call. So, the failure sounds like an encoder failure; the encoders are attached to

Mydata (TP9-2U) problem

Electronics Forum | Mon May 13 10:08:44 EDT 2013 | rgduval

I've heard that MyData is no longer supporting the TP's, so, getting a new motor might be a difficult proposition. If you can find the motor manuf/part number on the motor itself, you can likely find it on line somewhere...Google the p/n should do i


mydata ribbon searches for Companies, Equipment, Machines, Suppliers & Information

PCB Handling Machine with CE

Software for SMT placement & AOI - Free Download.
Blackfox IPC Training & Certification

Best Reflow Oven
SMTAI 2024 - SMTA International

Have you found a solution to REDUCE DISPENSE REWORK? Your answer is here.
PCB separator

Internet marketing services for manufacturing companies