Full Site - : mydata theta tp9 (Page 14 of 32)

Mydata TP9-2 Help

Electronics Forum | Mon Aug 06 18:58:12 EDT 2007 | edruppert

This message indicates that the Peak to Peak voltage for the x axis motor encoder is too low. Possible cable/encoder or MOT1 board problem. Machine will either exhibit this during intialization or while running. Diagnostics in service routine may he

reviews on pick and place machines

Electronics Forum | Mon Nov 12 10:28:22 EST 2007 | chrisruizuci

i just wanted to get others input on the MyData TP9 and Philips Topaz. Any advise at all would be helpfull.

MyData TP9-UFP Networking

Electronics Forum | Wed Dec 07 13:35:11 EST 2011 | cyber_wolf

Just curious, Why do you need to attach one machine to a PC ? Throw the data on a floppy and call it a day.

Mydata (TP9-2U) problem

Electronics Forum | Tue May 07 14:33:57 EDT 2013 | cyber_wolf

The "lowest" acceleration is probably causing your problem. Switch it to the next fastest setting and see what happens

MyData TP9 dead?

Electronics Forum | Thu Feb 06 14:01:55 EST 2014 | rgduval

1. Fuse 2. Power Supply 3. Power Distribution card 4. Booster Start by checking all of the fuses on the front of the power supply (accessed by removing the front cover of the machine). Then, check all of the fuses on the first card in the MOT bay.

SMT Equipment Service

Electronics Forum | Wed Feb 26 15:56:54 EST 2014 | rgduval

If Chris can't help you with your TP9, check out Lewis and Clark (www.lewis-clark.com). They've been working with MyData's for quite awhile. I receive no benefit from this recommendation. Cheers, ..rob

MyData TP9-UFP : Optical Centering Calibration Question

Electronics Forum | Fri Oct 17 09:38:07 EDT 2014 | rgduval

Are you able to turn off mechanical centering? Or can you adjust the settings?

MyData TP9-UFP : Optical Centering Calibration Question

Electronics Forum | Fri Oct 17 12:48:59 EDT 2014 | cyber_wolf

The only reason you would need to run this calibration is if the camera was replaced or the centering camera got whacked which is highly unlikely. If your placements are off, put an offset in the parameter file.

Mydata TP9-UFP problem - Can't reach tool bank

Electronics Forum | Mon Oct 22 16:33:14 EDT 2018 | tey422

To narrow down the cause. Have you test it on all your tools? If only particular tool(s) having issue, then it might be tool that's having the problem.

Mydata TP9-UFP problem - Can't reach tool bank

Electronics Forum | Tue Oct 23 00:52:16 EDT 2018 | filipblad

Yes, for all tools... The tool head stops just above the tool