Full Site - : mydata tp11 -ufp mouse (Page 5 of 5)

Mydata TP9-2 and TP11-UFP difference

Electronics Forum | Wed Jul 17 18:00:37 EDT 2019 | rgduval

Generally, the machines can place the same types/sizes of components. The advantage with the 11 is that you can have more magazines loaded with more components, and build larger assemblies more efficiently. The -9, though, will get you through near

Mydata TP9-2 and TP11-UFP difference

Electronics Forum | Thu Jul 18 17:06:19 EDT 2019 | spoiltforchoice

I can't imagine anything more tedious than continuously swapping feeders during a build (unless your panels are 10mins++) and the very suggestion this was a good idea when were were looking at MY's was comical to me. You should expect all TP series

Mydata TP11 UFP hardware initiation failure

Electronics Forum | Wed Jul 26 16:08:29 EDT 2006 | ev

My focus has moved to the X motor itself. The one common factor in this paricular problem has been the time of year. The day was a particularly hot day with high humidity. Even though there is a "Xfan" connection on the PIAB board I do not believe th

Re: Installing TPSys

Electronics Forum | Fri Jul 16 05:48:06 EDT 1999 | Wayne Sanita

Give Mydata a call as Scott said, they will take step by step over the phone. Wayne | | I was wondering if someone could help me with a little problem I am Having with a MyData TP-11 UFP running TPSys 1.4.2. Early this week the machine crashed an

Mydata TP9-2 and TP11-UFP difference

Electronics Forum | Thu Jul 18 17:38:27 EDT 2019 | rgduval

Not swapping out feeders....swapping out magazines. It only works well if you have enough extra mags to load all the feeders on. And is a viable solution if your position limited on your machine. Before the advent of Aegis feeders for My machine

Re: Installing TPSys

Electronics Forum | Thu Jul 15 21:10:53 EDT 1999 | Scott McKee

| I was wondering if someone could help me with a little problem I am Having with a MyData TP-11 UFP running TPSys 1.4.2. Early this week the machine crashed and I had to reload the software. I re-insatalled Venix then the CP4 driver then TPsys and S

Mydata TP11-UFP won't initialize

Electronics Forum | Thu Jan 06 12:41:37 EST 2011 | bk

That depends on what service screen you are using there are 2 of them.One is the exit to service under your exit prompt. The other is an extended version of the service program and you have to exit tpsys under the exit prompt and type in service -x w