Full Site - : mydata tp11 cache (Page 9 of 13)

MYDATA TP11 - Motor Controller M error

Electronics Forum | Fri Jun 03 14:21:48 EDT 2011 | rgduval

I haven't seen that particular fail....but... What was the failure with the M controller? Might try moving your MOT cards around, to see if the failure follows one particular card. If so, you'll know you need a new MOT card. That might satisfy th

MYDATA TP11 - Motor Controller M error

Electronics Forum | Fri Jun 03 15:19:19 EDT 2011 | jeremymc

After reseating the M controller boards I was able to get further than I had previously, no save status error, and was given an error about the voltage being wrong. During my last run my company had an electrician in to rewire somethings and put a

transducers out of sync error, Mydata TP-11

Electronics Forum | Tue Feb 28 07:31:40 EST 2012 | bk

I'm assuming it's your x wagon tranducers that are out of synch. So the first place to start is look at your couplings on both x motors and make sure one of them isn't broken or starting to break. After that i would try swapping out your x board with

Looking for a Mydata TP-11

Electronics Forum | Wed May 22 12:40:00 EDT 2013 | cyber_wolf

I like that idea. Usually when I post a wanted add in the equipment section I get several e-mails from places like Yum Yum's House of Good Luck SMT Equipment. I'm not saying there is anything wrong with that...it's just that the shipping charge is n

Using Stripfeeders on MyData Tray Wagons

Electronics Forum | Tue Jun 24 11:58:55 EDT 2014 | markhoch

We had both a MY15 and a TP11 both with tray wagons and we taped strips to the tray wagon all the time with great success. we used double sided tape, sometimes with magnets, and then created "trays" as if the tape strip was a matrix tray. (1 x 10,15

Hardware initiation failiure on start up (mydata TP11 )

Electronics Forum | Tue Oct 22 21:24:02 EDT 2019 | richgreen01

Hi All I have the above machine and every day on start up i get the failed to initiate hardware message.I have been getting around this by re initiating the motor controllers and it is good to go after this.Does anyone know the causes of the initiat

Mydata TP11 25VDC+ Rail not working

Electronics Forum | Thu Mar 19 21:06:19 EDT 2020 | sarason

In circumstances like these immediately switch off and remove your power supply , I often build a test harness because the damage to an expensive and unique machine is not woth the trouble of shotgun repair. Dead resistors in the voltage sense rail.

Mydata TP11 E-stop not released

Electronics Forum | Mon Oct 12 17:25:09 EDT 2020 | rgduval

Release the e-stops :) Chances are pretty good that one or more of the e-stop switches is going bad. Pop them off, and measure with an ohm-meter to figure out which one it is, and replace. I don't recall anything in the software that identified wh

Mydata TP11-UFP F-MOT1-38/245

Electronics Forum | Mon Oct 25 11:20:52 EDT 2021 | bk

The 245 error is with your x belt motor not the x wagon motor. double check all the fuses on the back of the machine where your power comes in there should be 3 of them. if you haven't changed your blue cables in a while I would change those out. you

Mydata technical support ?

Electronics Forum | Fri Oct 07 12:13:39 EDT 2005 | jbrower

My experience with MYDATA has been good. Tech support has always answered my questions promptly and steered me in the right direction when I was at an impass. All in all the tech support department is great. Just my opinion and experiences. My curr


mydata tp11 cache searches for Companies, Equipment, Machines, Suppliers & Information