Electronics Forum | Mon Aug 17 11:35:57 EDT 2020 | artem
Hello, I have some troubles with my MyData TP11-UFP with the precision of the placement. All the parts which are mechanically centered are slightly misaligned. Attached are some pictures of 0603 and a SOT23 part. I have made the calibration but it
Electronics Forum | Fri Dec 28 13:11:13 EST 2001 | cyber_wolf
Chris, I have worked with all kinds of Mydata's TP9,TP11,MY series machine for years. I have ran them, programmed them,and had just about every nut, bolt,motor, and circuit board out of them at one time or another.I have also written specialized mai
Electronics Forum | Wed Apr 06 09:16:31 EDT 2005 | blueflag
Ive just checked all the cables that i can see and there seems to be nothing wrong. Have just put a brand new fuse in to mot z card and it has blown it. machine boots up, initiate the hardware and everything goes ok until it does the z height then i
Electronics Forum | Tue Nov 15 06:46:41 EST 2005 | cyber_wolf
We have an earlier version of TPSYS. 2.4.1c We see this happen occasionally as well. It only seems to happen on our MY-12 machine. Our TP-11's never do it to my knowledge. I highly doubt that it is isolated to your company. If your machines are new,
Electronics Forum | Thu Jul 20 10:48:43 EDT 2006 | pms
Ev, This error could be caused by any number of problems. Is there an error message in the message window before hardware initiation error? If so, what is it? A failure in any axis (x,y,z,c,theta,y-wagon,tray-wagon) could cause your symptom. Paul
Electronics Forum | Tue Jan 04 13:00:07 EST 2011 | bk
The only x fan i can think of would be the x belt motor fan which is on the back of the black box sticking out of the back of the machine. If it's a heat issue then first thing to do is replace the 2 filters behind the 2 vented covers located on the
Electronics Forum | Fri Jun 03 14:21:48 EDT 2011 | rgduval
I haven't seen that particular fail....but... What was the failure with the M controller? Might try moving your MOT cards around, to see if the failure follows one particular card. If so, you'll know you need a new MOT card. That might satisfy th
Electronics Forum | Fri Jun 03 15:19:19 EDT 2011 | jeremymc
After reseating the M controller boards I was able to get further than I had previously, no save status error, and was given an error about the voltage being wrong. During my last run my company had an electrician in to rewire somethings and put a
Electronics Forum | Tue Feb 28 07:31:40 EST 2012 | bk
I'm assuming it's your x wagon tranducers that are out of synch. So the first place to start is look at your couplings on both x motors and make sure one of them isn't broken or starting to break. After that i would try swapping out your x board with
Electronics Forum | Wed May 22 12:40:00 EDT 2013 | cyber_wolf
I like that idea. Usually when I post a wanted add in the equipment section I get several e-mails from places like Yum Yum's House of Good Luck SMT Equipment. I'm not saying there is anything wrong with that...it's just that the shipping charge is n