Full Site - : mydata tp11 offline (Page 11 of 20)

Hardware initiation failiure on start up (mydata TP11 )

Electronics Forum | Wed Oct 23 15:22:11 EDT 2019 | bk

There should be some other error message also with the hardware initiation error. This will help us narrow down your problem

Mydata TP11-UFP F-MOT1-38/245

Electronics Forum | Fri Oct 29 17:48:46 EDT 2021 | artem

Hello, I have found the problem. The capacitors on the PAIB board were leaking. They have even demaged some traces and vias on the PCB and the -5V supply on the PAIB board was not working anymore. Got it working again :)

MYDATA TM FEEDERS WITH MY SERIES MACHINES

Electronics Forum | Sat Nov 20 04:32:45 EST 2021 | smtusa

Will TM series feeders (from a TP-11) run slow on a MY series machines with HYDRA head? Are there any MY series machines with dual HYDRA heads?

MYDATA TM FEEDERS WITH MY SERIES MACHINES

Electronics Forum | Tue Nov 23 02:23:27 EST 2021 | SMTA-64387687

The TM magazines will work exactly the same on the newer machines, as they did on your TP-11. The MY100, MY200, and MY300 series machines are all available with 2 heads, Midas and Hydra.

Mydata TP11 1995

Electronics Forum | Thu Apr 07 07:17:54 EDT 2005 | cyber_wolf

Colin, At this point you may consider calling in Mydata. I told you the basic things I have seen cause your problems. It sounds as if you may have a bad card, and or short somewhere. Possibilities: XWB Small booster on the front of the computer bo

MYData issue

Electronics Forum | Tue Jun 19 11:28:10 EDT 2007 | kpm135

I am fairly new to the MYData machine. The TP11 we have just started generating the following error: W-MIPR-20:System voltage BATTERY measured 14.59V (outside limits). After talking with the operators and reading the manual I believe the problem may

MyData placement precision / alignment

Electronics Forum | Mon Aug 17 11:35:57 EDT 2020 | artem

Hello, I have some troubles with my MyData TP11-UFP with the precision of the placement. All the parts which are mechanically centered are slightly misaligned. Attached are some pictures of 0603 and a SOT23 part. I have made the calibration but it

My Data

Electronics Forum | Fri Dec 28 13:11:13 EST 2001 | cyber_wolf

Chris, I have worked with all kinds of Mydata's TP9,TP11,MY series machine for years. I have ran them, programmed them,and had just about every nut, bolt,motor, and circuit board out of them at one time or another.I have also written specialized mai

Mydata TP11 1995

Electronics Forum | Wed Apr 06 09:16:31 EDT 2005 | blueflag

Ive just checked all the cables that i can see and there seems to be nothing wrong. Have just put a brand new fuse in to mot z card and it has blown it. machine boots up, initiate the hardware and everything goes ok until it does the z height then i

MY12 tpsys shutdown

Electronics Forum | Tue Nov 15 06:46:41 EST 2005 | cyber_wolf

We have an earlier version of TPSYS. 2.4.1c We see this happen occasionally as well. It only seems to happen on our MY-12 machine. Our TP-11's never do it to my knowledge. I highly doubt that it is isolated to your company. If your machines are new,