Electronics Forum | Fri Oct 18 15:58:42 EDT 2019 | tech1
3 different A12 tools and the same error could be a problem with the tool holder or a parameter. I suppose the locking tabs in the holder could be worn or bent and you could try removing one of the pins from the tool and setting it in a different loc
Electronics Forum | Fri Oct 18 16:40:32 EDT 2019 | tey422
Whenever you are not sure if a part is good or not. Try to use it on the 2nd machine which uses the same part to test it out. If it "test" part works fine on the 2nd machine then it would be ruled out as not the "root cause". In your case, you can t
Electronics Forum | Tue Jul 17 12:57:41 EDT 2007 | cyber_wolf
Is your machine a TP9 2U ? If you have a UFP or a MY series machine this condition usually points towards a bad X-wagon motor.
Electronics Forum | Wed Jul 18 07:36:20 EDT 2007 | allgood
Sorry I misunderstood, its a UFP. And yes it does wobble as you step from slot to slot and when you step through a pcb, not a huge wobble, more of a shimmy really.
Electronics Forum | Wed Jul 18 07:48:12 EDT 2007 | cyber_wolf
Bad small X motor most likely. Other possibilities: Bad cables Bad Card
Electronics Forum | Thu Jul 19 06:49:38 EDT 2007 | cyber_wolf
Chris, Are you sure about the joystick trackball statement? He said he is seing "bounce" when he steps through placements and when he trims mag positions. That would indicate a issue with the small x-mot system to me.
Electronics Forum | Thu Jul 19 06:57:15 EDT 2007 | cyber_wolf
Peter, GO TEST YOUR SMALL X-MOTOR IN THE SERVICE PROGRAM !!!!!! Do not start changing parameter files ! I assume that your machine worked fine at one time with the original parameter file.
Electronics Forum | Thu Jul 19 08:33:37 EDT 2007 | allgood
Ok I can get into the service program - under Motors there is only a single X motor listed. And what test can you do - seems that I can only display ranges and settings? No test as such?
Electronics Forum | Wed Jun 27 14:36:22 EDT 2012 | cyber_wolf
If the X axis is moving then maybe your Elmo is not adjusted correctly. There is a procedure to adjust it in the manual(assuming you have the original manual). The correct location is XGTS which is a white connector on the booster. The fans are 24V
Electronics Forum | Thu Oct 17 13:59:58 EDT 2019 | mendezt6
Trying to install A12 tool, fails to fetch tool. Error: Preliminary fetch failed, try to unlock tool manually.