Electronics Forum | Wed Jan 05 09:24:53 EST 2005 | cyber_wolf
Well...here is what I can tell you: I have over $40K worth of bent A12,A13,A14 tools.Yes you heard me right $40K worth. (Since 1995) Mydata used to make a repair kit to fix them but decided to quit. They tell me the reason they quit making the kit i
Electronics Forum | Fri Nov 22 00:09:29 EST 2019 | mk15
I am looking for some help for where to look to fix this MY15E problem. 1. after hardware initiation appear - F-MOT-MOVE X/250: Motor speed out of control (photo1). 2. in service mode when x motor initiate appear - F-MOT-MSETDYN X/12: No axis movemen
Electronics Forum | Fri Jul 20 07:09:29 EDT 2007 | chrispy1963
Sr. Tech, youre absolutely correct that the X-Wagon (pancake) motor is the one which will do final positioning when moving to a programmed position. The X Axis motor in back of the machine is used for rapid traverse of the axis. I was thinking more
Electronics Forum | Fri Jan 10 11:32:52 EST 2014 | rgduval
Hi, Hans, I would have suggested swapping the MOT card out to see if that fixes the issue (or, changing the MOT card with another one to isolate the card), but, it sounds like you've already done that. I'm surprised that MyData would point you towa
Electronics Forum | Mon Nov 25 02:15:07 EST 2019 | mk15
it is possible to test x belt motor and x wagon motor.
Electronics Forum | Wed Feb 28 07:30:26 EST 2007 | cyber_wolf
We recently scrapped our TP9-2U because of an issue similar to this. The X-axis would overshoot the pick and place positions. This particular machine(2U)only has 1 X motor. The UFP's and the MY machines have a small fine positioning motor that is on
Electronics Forum | Fri Oct 12 11:21:43 EDT 2018 | tech1
There are 2-X motors and numerous items that could be causing this: 1 of the X motors, 1 of the X transducers, 1 of the couplings connecting the motor and transducer, X Kevlar Belt. If you know how to go into the service portion of the software you
Electronics Forum | Wed Jul 15 17:02:06 EDT 2020 | tomdegas
Does anyone know where I can get a copy of the Mydata Software Related Procedures Manual? I am running Tps 2.8.1 and I need the procedure for calibrating the x-wagon camera (PVS).
Electronics Forum | Thu Jul 20 10:48:43 EDT 2006 | pms
Ev, This error could be caused by any number of problems. Is there an error message in the message window before hardware initiation error? If so, what is it? A failure in any axis (x,y,z,c,theta,y-wagon,tray-wagon) could cause your symptom. Paul
Electronics Forum | Fri Jul 04 07:11:43 EDT 2014 | padawanlinuxero
Hello We work with a TP9-4 and a MY12 both with tray wagons, I like a lot the tray wagon, for big components we use it, but like AVFM we build our own pallets, and some of them were big 3x30 array or even bigger all pallets were done in a ESD mater