Full Site - : mydata x wagon ribbon (Page 6 of 9)

Mydata - Level too high in pick

Electronics Forum | Thu Sep 19 10:27:10 EDT 2013 | rgduval

I believe there is a force calibration menu option in the maintenance menu. From the main screen, choose exit to maintenance to get into the maintenance menus. If you're still having force issues afterwards, you'll want to start hunting for broke

Mydata Line Scan

Electronics Forum | Thu May 13 12:24:26 EDT 2004 | cyber_wolf

We have an older line scan camera on our MY series machine.(The one that uses the X wagon trigger/encoder to turn on the line scan)When I go into the service program and turn the line scan camera to "camera action on" the LED's will only stay lit for

MYDATA My9 Theta error

Electronics Forum | Tue Nov 20 15:03:37 EST 2012 | jaimebc

Bruce, Since we had spares, I replaced the X wagon cables, XFMB cable, nothing. FFX Cable, nothing. Swapped mot cards, nothing. Vaccum seal, nothing.At this point I truly believe the problem is either on the theta encoder or the theta motor. Unfortu

Mycronic vs. Juki: Your Opinions?

Electronics Forum | Fri Mar 24 15:35:58 EDT 2023 | cyber_wolf

All of these components were replaced under warranty. I cant remember how long that was. I was working with the very first My12's. This machine was never reliable and there was always something broken. Anywhere I have ever been that had MY series mac

Mydata TP-11 Small X not working

Electronics Forum | Thu Mar 26 08:51:40 EDT 2009 | avalancher

Hi Sr. First suggestion is to call Mydata's phone support. With that said... Here is some ideas of what you could check: 1. Do you have power at the XWB board connector going to the motor (xxwm connector)? 2. Do you have power coming through the bl

Mydaya Camera issue

Electronics Forum | Sat Nov 26 10:17:04 EST 2005 | BillyD

All: I'm having a rough time with one of my Mydata cameras. Specifically, the X-wagon camera. I've got no video from it, no light from it, etc. I've checked all the connections, all seems fine, but it does not work. Does anyone know where there

Mydata (MY12) error-Frame Grab and Light Curtain

Electronics Forum | Tue Sep 22 16:39:10 EDT 2009 | rmitchell

Hi, We are getting a E-Hydra-1 Frame grabbing failed on caps and resistors and also a Light Curtain trigger X wagon. I spoke with mydata and they indicated the light curtain might be getting set off and causing the frame grabbing failure. I cleane

Mydata M12 issue

Electronics Forum | Tue Oct 27 11:20:16 EDT 2009 | smtspecialist

I had the same problem back in March with my MY12, since I have two identical lines i swapped things around until swapping the x-wagon motor (the one for fine movements). When I swapped the x-motor I move the problem from one line to the other gener

Mydata TP-11 Small X not working

Electronics Forum | Wed Mar 25 14:55:17 EDT 2009 | cyber_wolf

The small x motor quit working.It seems that there is no voltage going to the motor. Here is what I have done so far: *Verified that the motor is good. *Check pico fuses on the backplane *Verify voltages on backplane and on big booster. *Swap mot ca

MYDATA TP9-4 MI board

Electronics Forum | Tue Jun 01 08:42:08 EDT 2010 | rgduval

I'm randomly having some motor move errors, as well. If you swap your MOT board, and the problem continues, you're down to a couple of problems. Could be that the motor is getting ready to die on you. Could be an encoder problem. Or, could be som


mydata x wagon ribbon searches for Companies, Equipment, Machines, Suppliers & Information