Electronics Forum | Wed Nov 28 20:45:03 EST 2001 | dougk
We�ve also had glass diode difficulties- poor adhesion while all other parts are fine (including tall parts). I�ve received some interesting information from Heraeus: It seems the newer glues create a much stronger bond to SMD�s, except glass diodes.
Electronics Forum | Fri Jan 05 09:23:10 EST 2001 | Brian Toleno
While there may not be any specific requirement to cleaning prior to coating, cleaning an assembly prior to coating will only serve to increase the reliability and integrity of the coating. Some residues from low-solids fluxes can interact with conf
Electronics Forum | Wed Apr 13 18:28:21 EDT 2005 | RT
We have a situation where our customer returned a device (BGA) with a missing solder ball. The process is Copper-Nickel-Gold-Solderball. EDX revealed that no trace of gold nor solder material (lead-free balls). Could poor Au plating/adhesion cause
Electronics Forum | Fri Oct 08 09:43:27 EDT 2004 | davef
First, don't get too excited about the thermal capabilities of conductive epoxy. An epoxy like DuPont CB-100 increases the amount of heat conducted through the barrel, but many over estimate what it can do. Calculations show for a 0.020" drilled
Electronics Forum | Wed Sep 10 14:14:03 EDT 2008 | gregoryyork
Yes why did the Electroless Nickel layer split this is the ROOT cause. My guess is still that the resist was slightly miss registered over the copper and therefore poor adhesion of the Nickel ensued OR like I said originally the resist had contaminat
Electronics Forum | Wed Jun 03 15:22:12 EDT 1998 | Greg Curler
| | We have experienced poor adhesion of acrylic conformal coating to plastic bodied IC�s. The observed symptoms of this are a blistering or lifting of the coating at the surface of the component, although peel testing has revealed that this is not
Electronics Forum | Tue Jun 02 18:01:47 EDT 1998 | Earl Moon
| | | We have experienced poor adhesion of acrylic conformal coating to plastic bodied IC�s. The observed symptoms of this are a blistering or lifting of the coating at the surface of the component, although peel testing has revealed that this is no
Electronics Forum | Wed Jun 03 01:06:13 EDT 1998 | Mike Moninger
| We have experienced poor adhesion of acrylic conformal coating to plastic bodied IC�s. The observed symptoms of this are a blistering or lifting of the coating at the surface of the component, although peel testing has revealed that this is not al
Electronics Forum | Thu Oct 24 17:23:12 EDT 2002 | slthomas
The logical course seems like you would just back off on the shot size or go with a smaller diameter nozzle, but if this is something new and you've been running fine up until recently then something has changed. Check the condition of your nozzles.
Electronics Forum | Thu Oct 26 17:53:32 EDT 2000 | Dave F
John: I�m here. On "what do ya think about that one!..."??? Mutha, that sounds rat�s rump [as Dennis Miller says] ugly. On some boards, we paste a cuppla chips on the break-away panels and then torque the chips from the board after cure. We use the