Industry Directory | Manufacturer
Mingke is a manufacturer and supplier of nurse call system, hospital intercom, medical pager, nurse call button, wireless ward pager and wired intercom in china.
A500, A600, A800 - 5, 6 or 8 top/bottom cooling zones. Heating System: Up to eight groups of top and bottom forced hot air convection heating zones. Patented heating plates in each zone uniformly transfer heat to the PCBs using forced hot air co
S8, S10, S12 - 8, 10 or 12 top/bottom cooling zones. Heating System: Up to twelve groups of top and bottom forced hot air convection heating zones. Patented heating plates in each zone uniformly transfer heat to the PCBs using forced hot air con
Electronics Forum | Mon Oct 10 15:24:15 EDT 2005 | zl3vlf
Hello to all! Our Fuji FIP-3 placement machine has come up with a servo alarm (X2-axis) whenever we try to run the machine. The manuals don't go into a lot of detail as to the cause of this problem, but there is plenty of information on what the X2
Electronics Forum | Mon Aug 31 11:52:28 EDT 2020 | inspiredmorris20
Hello Jon, I appreciate your reply, correct there are 2 red (24v) that control the main power and 2 blue (they control the power to the units operation keys ready, start, stop, reset, change feeders.) additionally there is a red jumper wire on the E
Used SMT Equipment | Board Cleaners
• Vintage 2008 • PLC based Control System • 480V AC 60Hz • Auto Stop/Stand by Mode • Final Rinse low flow sensor and alarm • Mach II Drying System • 2 upper, 2 lower jet manifolds • 15 HP blower upgrade • 18” Off Load Extension • Integrated
Used SMT Equipment | Labeling Systems
CTI Systems In-Line Laser Marker Model: A-MS2-10W/C02-2-1M-3387 Vintage: 2014 10 Watt C02 Synrad Laser Fume Extractor 1.0Meter wide footprint with 16″ W x 18″L PCB capability Fiducial correction and live teach/view camera. Secondar
Industry News | 2020-12-20 23:40:23.0
Easily Installed Excel Cell Emergency Switches Available in 22mm, O25mm and O30mm Mounting Diameters
Industry News | 2020-12-21 09:13:06.0
Easily Installed Excel Cell Emergency Switches Available in 22mm, O25mm and O30mm Mounting Diameters
Parts & Supplies | Pick and Place/Feeders
JUKI JX-100 40086822 CONVEYOR BELT 40084841 EF ARRANGE CBL 1 BLACKET ASM 40084842 FEEDER CUTTER(F) WIRE ASM 40084843 FEEDER CUTTER(R) WIRE ASM 40084844 ELEC BANK RELAY WIRE ASM 40085026 INTAKE_VALVE_BACK_UP 40085027 EXHAUST_VALVE_BACK_UP 40085
Parts & Supplies | Pick and Place/Feeders
JUKI FEEDER FF443S JUKI FF44FR Feeder JUKI FEEDER FF443S E7203706RB0 UPPER COVER 4412ST ASM. 1 E7203706RBC UPPER COVER 4444OP ASM. 1 E7211706RA0 UP COVER HOOK 44 ASM. 1 E73107060A0 TAPE HOLDER 44 ASM. 1 E6000706RA0 FEEDER BASE 32
Technical Library | 2019-12-12 02:43:44.0
Today we discuss the reason that causes temperature humidity chamber to alarm,In most cases, the equipment alarm is caused by the improper operation in the process of use, which mainly includes following reasons:that are refrigeration system, temperature system and circulating system. First, Refrigeration system 1, refrigeration compressor overpressure alarm. If the refrigerant pressure exceeds the set value, it will stop and alarm at the same time. At this time, the fault must be eliminated and then manually reset. 2, short phase power supply, phase sequence alarm. When the external power supply of the equipment is out of phase or the phase sequence is changed, it will stop and alarm at the same time. 3. The circulating cooling water is short of water to alarm. When the water pressure of the cooling circulating water system is insufficient, it will stop and alarm at the same time, and it must wait for the fault to be eliminated and reset at the same time before it could run normally. 4, refrigeration compressor overheating alarm. When the coil of the compressor is overheated and the power supply of the line is not normal, it will stop and alarm at the same time. Second, Temperature system 1, the overtemperature alarm in the chamber. The sensors in the channel and the sample area are equipped with overtemperature protection devices, and there are also overtemperature protecter on the control panel. When the temperature in the working chamber exceeds the setting value on the controller, it will stop and alarm. 2. sample overtemperature protection. When the temperature in the sample area exceeds the protection temperature set by the controller, it will stop and alarm at the same time. The overtemperature protection of the sample is divided into upper limit protection and lower limit protection, which can be set according to the demand, Third,Circulating system 1. The alarm is caused by the overheating of the circulating fan. When the coil of the fan is over-heated, the alarm will be stopped at the same time. 2. The fan over-current alarm. When the current of the fan exceeds the allowable value, the alarm is stopped at the same time, and the normal operation can only be carried out after the fault maintenance of the overcurrent is completed. This is what we talk about today,if you have more questions,let us know.
A500, A600, A800 - 5, 6 or 8 top/bottom cooling zones. Heating System: Up to eight groups of top and bottom forced hot air convection heating zones. Patented heating plates in each zone uniformly transfer heat to the PCBs using forced hot air co
S8, S10, S12 - 8, 10 or 12 top/bottom cooling zones. Heating System: Up to twelve groups of top and bottom forced hot air convection heating zones. Patented heating plates in each zone uniformly transfer heat to the PCBs using forced hot air con
Career Center | 10th of ramadan, Egypt | Engineering,Maintenance,Management,Production
• Excellent Analytical, inter-personal and communication skills • Ability to work effectively in teamwork • Ability to set and achieve goals and work under pressure • Learn quickly, hard worker • Capable of study and research acti
GPD Global | https://www.gpd-global.com/co_website/pdf/doc/Dispense-System-User-Guide-22100079K.pdf
...................................................................................................................... 4.5 Stop Operations ............................................................................................................ 4.6 Safety Systems
ASYMTEK Products | Nordson Electronics Solutions | https://www.nordson.com/en/divisions/adhesive-dispensing-systems/products/controllers-and-control-systems/accubar-bar-code-verifier
; and ladder or picket-fence scanning. Protect product quality with faulty code detection that triggers an alarm, machine stop, ejector or marker