Full Site - : reloading (Page 10 of 22)

DEK 265 GSX missprint

Electronics Forum | Tue Mar 22 16:12:30 EDT 2022 | dekhead

Most likely corrupted vision calibration. Reload backup calibration from floppy (of available), rerun calibration ("Calibrate Vision")

Universal 6421D THTCommunications Error

Electronics Forum | Wed Dec 14 13:37:52 EST 2022 | assuredtech

What programming / communication software are you using? Does the machine have the J11 Controller? When changing the batteries you most likely lost the Executive file (machine configuration file), so you need to reset the controller and reload your E

Tact Time Estimates

Electronics Forum | Mon Mar 10 10:28:23 EST 2003 | pjc

Tact times published by placement equipment suppliers usually do not account for board load/unload. Placement time standards set for your boards must include load/unload time. I measure from first fiducial read on board 1 to first fiducial read on bo

Hollis PT500 system software Q.

Electronics Forum | Tue Jan 27 03:59:51 EST 2004 | KevC

Hi lads, Can anyone tell me a bit about PT500 application software? I recently had to replace the Hard drive in the host PC for our wave. I re-loaded the system software and re-configured. One thing I noticed however is in the "Calibrate T/C's" opti

Quad 2C ICOS Error

Electronics Forum | Mon Nov 21 10:56:32 EST 2011 | gosswald

I have been able to get the machine to run by using the teach feature in Central Controller. The fiducials coordinates are there from Auto Program even though they won’t run. Another problem I have with this is the board fails the visual inspection i

DEK 265 Printer Error

Electronics Forum | Tue May 27 15:11:13 EDT 2014 | dekhead

1. Rising Table Position error is, most commonly an issue of motor movement or sensor(s); Not receiving an expected input (sensor input / 'DONE' signal) in expected period of time. Try homing table in Diagnostics see if it moves and what movements ar

X-ray information CRX2000

Electronics Forum | Tue Jan 13 12:58:26 EST 2004 | JA

Juan, Try Hamamatsu directly. (908) 231-1116 e-mail: usa@hamamatsu.com Ask for "RE-LOAD" pricing. Make sure you have the tube serial number and model available. Some units cannot be re-used. You will find the serial # on the side of tube housing. J

Dek 265

Electronics Forum | Mon Feb 02 14:06:27 EST 2004 | jsk

I did reload mint. When i do this the machine runs fine for about 15 minutes, but i have to continue loading boards. If I let the machine idle for 3-5 minutes, i get the error. We are a low volume manufacturing company, so on a 20 piece run i will re

De Haart printer expert

Electronics Forum | Fri Feb 13 04:09:52 EST 2004 | patthemack

New update: By playing around with some settings in the software, we've been able to get the z-axis to work. This makes me think that if we reload the software, the problem may be fixed. Got any ideas as to where I can get a copy of the MPC-29 softwa

Splicing SMT tape & reel

Electronics Forum | Wed Mar 03 13:50:37 EST 2004 | gregp

The root cause of your problem is your placement equipment. It is not designed for continuous production during component replenishment. Feeders that can be removed, reloaded, and placed back on the machine while the machine is running (without mis


reloading searches for Companies, Equipment, Machines, Suppliers & Information

Online Equipment Auction of Altronic: Small-Batch Surface Mount & Assembly Facility

World's Best Reflow Oven Customizable for Unique Applications
SMT feeders

Wave Soldering 101 Training Course
2024 Eptac IPC Certification Training Schedule

Software for SMT placement & AOI - Free Download.
SMT feeders

Software programs for SMT placement and AOI Inspection machines from CAD or Gerber.