Electronics Forum | Wed Jul 24 15:33:49 EDT 2019 | weglimir
Hello, We've got this DEK256GSX quite some time ago, and finally we've managed to start and initialize it. However the problem is that we don't know edit password, and re-seller that we initially bought this unit from doesn't know the password as w
Electronics Forum | Tue Jul 30 23:51:06 EDT 2019 | rob1
Have you tried entering "DEK" as the password?
Used SMT Equipment | Pick and Place/Feeders
Universal GSM2 Pick and Place Machine Serial Numbers: 10056299 Model Number: GSM2 Product Code: R4681A Year 2004 Software: UPS+ Version: 6.1.2.3 Dual Beam 7 Spindle FlexJet - Front Beam 1 7 Spindle FlexJet - Rear Beam 2 2 Upward Looking Came
Used SMT Equipment | Screen Printers
Hello and thank you for your interest in our MPM UP2000 Hie Stencil Printer For Sale. The machine was recently taken out of an SMT Manufacturing facility which closed. It is located at our facility where it was powered up, cycled, and zero reset by a
Industry News | 2018-06-14 12:10:52.0
Now available from FKN Systek, Stackable PCB Transport and Storage Racks made of conductive material for safe and convenient handling of Printed Circuit Cards during assembly. These Racks will hold up to 50 PCBs from 2” to 9.8” (5 to 25 cm) wide. Racks are made of conductive plastic temperature rated to 176 O F, Surface resistance
Industry News | 2015-03-10 13:55:36.0
Count On Tools Inc., a leading provider of precision components and SMT spare parts, now carries PB Swiss Tools’ expanded line of MecaTorque torque tools. The new line of analog torque wrench screwdrivers is simple, reliable and safe for application. The MecaTorque torque handles with preset trigger value are ideal for all applications requiring the same torque at all times, such as in machining or assembly operations. The expanded product range for low to high torque with interchangeable blades or in bit holder versions provides the correct tool for every application.
Parts & Supplies | SMT Equipment
USE ALTENATIVE PART FUJI RELAY G2R-212S-VNUS DC12V > USE ALTENATIVE PART FUJI RELAY G2R-112S-DC24V TO R2016A > USE ALTENATIVE FUJI RELAY G2R-212S-DC24V TO R2017A > USE ALTENATIVE FUJI RELAY G3R-102SLN DC24V/2A FUJI
Parts & Supplies | SMT Equipment
USE ALTENATIVE PART FUJI RELAY G2R-212S-VNUS DC12V > USE ALTENATIVE PART FUJI RELAY G2R-112S-DC24V TO R2016A > USE ALTENATIVE FUJI RELAY G2R-212S-DC24V TO R2017A > USE ALTENATIVE FUJI RELAY G3R-102SLN DC24V/2A FUJI
Technical Library | 2019-12-12 02:43:44.0
Today we discuss the reason that causes temperature humidity chamber to alarm,In most cases, the equipment alarm is caused by the improper operation in the process of use, which mainly includes following reasons:that are refrigeration system, temperature system and circulating system. First, Refrigeration system 1, refrigeration compressor overpressure alarm. If the refrigerant pressure exceeds the set value, it will stop and alarm at the same time. At this time, the fault must be eliminated and then manually reset. 2, short phase power supply, phase sequence alarm. When the external power supply of the equipment is out of phase or the phase sequence is changed, it will stop and alarm at the same time. 3. The circulating cooling water is short of water to alarm. When the water pressure of the cooling circulating water system is insufficient, it will stop and alarm at the same time, and it must wait for the fault to be eliminated and reset at the same time before it could run normally. 4, refrigeration compressor overheating alarm. When the coil of the compressor is overheated and the power supply of the line is not normal, it will stop and alarm at the same time. Second, Temperature system 1, the overtemperature alarm in the chamber. The sensors in the channel and the sample area are equipped with overtemperature protection devices, and there are also overtemperature protecter on the control panel. When the temperature in the working chamber exceeds the setting value on the controller, it will stop and alarm. 2. sample overtemperature protection. When the temperature in the sample area exceeds the protection temperature set by the controller, it will stop and alarm at the same time. The overtemperature protection of the sample is divided into upper limit protection and lower limit protection, which can be set according to the demand, Third,Circulating system 1. The alarm is caused by the overheating of the circulating fan. When the coil of the fan is over-heated, the alarm will be stopped at the same time. 2. The fan over-current alarm. When the current of the fan exceeds the allowable value, the alarm is stopped at the same time, and the normal operation can only be carried out after the fault maintenance of the overcurrent is completed. This is what we talk about today,if you have more questions,let us know.
Technical Library | 2019-04-08 23:21:29.0
Climatest Symor® adopts molecular sieve to dry air, the whole system is controlled by microcomputer, when humidity is high, It will start to absorb moisture,when the humidity reach the pre-set value, it will stop absorbing, and then discharge the water to outside the cabinet by heating,again and again by automatic control. The most effective and environment-friendly moisture-absorbing desiccant is molecular sieve, molecular sieve is the microporous crystal material synthesized by silicon and aluminium oxide. In order to keep the crystal net discharge to be zero, atoms with cations are located in the crystal structure.and the cation used in these synthetic crystals is usually sodium. At present, there are two kinds of molecular sieves widely used in the dry box industry: Class A and Class X. Molecular sieves are synthesized, shaped and activated under strictly controlled production processes. The whole controlled sythesis process can ensure consistency of the three-dimensional pore size. 3A molecular sieve pore size is 3 angstroms, 4A molecular sieve pore size is 4 angstroms; 13X molecular sieve pore size is 8.5 angstroms. The working principle of molecular sieve: Molecular sieves adsorb molecules onto the crystal surface by physical attraction force. Since 95% surface area of the molecular sieve is within aperture,it needs to screen the adjacent molecules by different size. Only small size molecules can enter into the inner adsorption surface of the molecular sieve through the crystal aperture. This selective adsorption phenomenon is called molecular sieve effect. The molecular sieve adsorption capacity and charge density (polarity) are further related to the adsorbed molecules. The molecular sieves can further distinguish which of the mixed molecules can be adsorbed and determine to what extent the charge density can allow the molecules to be adsorbed onto the crystal. Water molecules are particularly small (2.6 angstroms), that belong to highly polar molecules (very strong positive and negative electron density), and are easily adsorbed by molecular sieves, even under very low moisture condition,once the water molecules are adsorbed,they will be firmly fixed on the crystal. The environment-friendly moisture absorption device is equipped with molecular sieve. When it’s absorbing, the memory alloy controller is in tensile state, and the spring is in contractive state,which just make the valve contact the outer baffle, this insulates the outside air from inside dry box air to achieve dehumidification purpose; and after molecular sieve absorbed moisture inside dry box and become saturated, the program will automatically control the memory alloy device to shrink it so that the valve reaches the inner baffle position. Meanwhile, due to the shrinkage of the memory alloy, the spring is stretched and the valve is pulled out of the outer baffle,so that the moisture in molecular sieve will be discharged into the outside. after the dehumidifying process finished, the program automatically control and reset the memory alloy and spring,to restart absorbing status.
Hello and thank you for your interest in our MPM UP2000 Hie Stencil Printer For Sale. The machine was recently taken out of an SMT Manufacturing facility which closed. It is located at our facility where it was powered up, cycled, and zero reset by a
Career Center | Clearwater, Florida USA | Maintenance,Production,Quality Control,Technical Support
I have approximately 14 years experience in the Electronics manufacturing industry. I have experience from manual assembly to machine technical support for SMT eqiupment. I also have some experience with AI equipment. I have Automatic Optical Inspect
Career Center | Temple Hills, Maryland USA | Maintenance,Management,Technical Support
• Installing Network Hardware • Trouble shooting – Hardware and software • System Administration • Procurement Management • Naval Facilities Management • Great Customer Service
Heller Industries Inc. | https://hellerindustries.com/parts/586444/
586444 - BLUE RESET SWITCH Phone 1-973-377-6800 Company About News Events New Equipment Convection Reflow Ovens Reflow Oven MK7 -New
Qinyi Electronics Co.,Ltd | https://www.qy-smt.com/shop/e5215706000-hook-reset-shaft-199165?page=592&order=name+asc
JUKI HOOK RESET SHAFT E5215706000 | QYSMT × Home About US ABOUT US FAQ SMT spare parts SMT Surplus equipments SMT peripheral equipments News Contact US 0 0 Sign in Contact Us Products HOOK RESET SHAFT Public Pricelist Public Pricelist HOOK RESET SHAFT