Full Site - : results of ionic contamination in water (Page 1 of 11)

Boston Chapter Webinar: Cleaning Chemistry For PWB and Rework - Part 2, session 1

Events Calendar | Tue Apr 13 00:00:00 EDT 2021 - Tue Apr 13 00:00:00 EDT 2021 | ,

Boston Chapter Webinar: Cleaning Chemistry For PWB and Rework - Part 2, session 1

Surface Mount Technology Association (SMTA)

Boston Chapter Webinar: Cleaning Chemistry For PWB and Rework - Part 2, session 2

Events Calendar | Tue Apr 13 00:00:00 EDT 2021 - Tue Apr 13 00:00:00 EDT 2021 | ,

Boston Chapter Webinar: Cleaning Chemistry For PWB and Rework - Part 2, session 2

Surface Mount Technology Association (SMTA)

GE IC695CHS012IC695CHS007IC695CHS016 Good color of the base

GE IC695CHS012IC695CHS007IC695CHS016 Good color of the base

New Equipment | Industrial Automation

General Electric  GIVEN YOUR BEST ! PLEASES mailto:unity@mvme.cn Contact: Sandy Lin Email:unity@mvme.cn Skype:onlywnn_1 Telegram:+8618020776786 Mobile(Whatsapp): (+86)-18020776786 QQ :2851195456 General Electric Company is an Americanmultinati

XIAMEN YUEHANG COMPUTER ENGINEERING CO.LTD.

Dissolution of Metal Foils in Common Beverages

Technical Library | 2016-07-07 15:37:18.0

How susceptible are the metals used in modern electronics manufacturing to corrosion by common beverages? This is a question of interest, especially to manufacturers, retailers and to a certain extent end customers. In this study the dissolution of aluminum, copper, gold, iron, lead, nickel, SAC305 solder, silver, tin and zinc was examined. Individual foils of these materials were fully immersed in one of sixteen chosen beverages and heated for 3 days at 40°C. The resulting solutions were analyzed using ICP-OES. The data were examined in light of the known pH, conductivity and ionic contents of the beverages, determined in previous work. Conclusions about the relative susceptibility to corrosion of the various metals and the corrosive power of the different beverages are made.

BlackBerry Limited

Process Control of Ionic Contamination Achieving 6-Sigma Criteria in The Assembly of Electronic Circuits

Technical Library | 2018-11-29 13:43:54.0

Ionic contamination testing as a process control tool a newly developed testing protocol based on IPC-TM 650 2.3.25, was established to enable monitoring of ionic contamination within series production. The testing procedure was successfully implemented within the production of high reliability, safety critical electronic circuits, involving multiple production sites around the world. I will be shown in this paper that the test protocol is capable for meeting Six-Sigma-Criteria.

Robert Bosch LLC Automotive Electronics Division

Reduce Pollution of Process Gasses in an Air Reflow Oven

Technical Library | 2019-07-02 23:02:05.0

The introduction of lead-free solders resulted in a selection of different chemistries for solder pastes. The higher melting points of lead-free alloys required thermal heat resistant rosin systems and activators that are active at elevated temperatures. As a result, more frequent maintenance of the filtration systems is required and machine downtime is increased.Last year a different method of cleaning reflow ovens was introduced. Instead of cooling down the process gasses to condensate the residues, a catalyst was used to maintain the clean oven. Catalytic thermal oxidation of residues in the nitrogen atmosphere resulted in cleaner heating zones. The residues were transformed into carbon dioxide. This remaining small amount of char was collected in the catalyst. In air ovens the catalyst was not seen as a beneficial option because the air extracted out of the oven was immediately exhausted into the environment. When a catalyst is used in an air environment there is not only the carbon dioxide residues, but also water. When a catalyst is used in an air reflow oven the question is where the water is going to. Will it condensate in the process part of the oven or is the gas temperature high enough to keep it out of the process area? A major benefit of using a catalyst to clean the air before it is exhausted into the environment is that the air pollution is reduced dramatically. This will make environmental engineers happy and result in less pollution of our nature. Apart from this, the exhaust tubes remain clean which reduces the maintenance of air ovens.This paper will give more detailed information of catalyst systems during development and performance in production lines.

Vitronics Soltec

Monitors Keep Track of PCB Contamination

Industry News | 2003-06-04 09:11:10.0

Concoat Systems has further expanded and enhanced its CM range of contamination testers (or contaminometers).

Concoat Ltd.

Materials and Measurement in Brighton

Industry News | 2003-05-05 08:32:30.0

Nepcon UK in Brighton will host the latest in electronics materials and electronics reliability measurement equipment from Concoat.

Concoat Ltd.

Mike Konrad to Present “Cleaning in a World of No-Clean” at the SMTA Intermountain Vendor Day in Idaho

Industry News | 2012-03-27 14:08:21.0

Aqueous Technologies announces that CEO Michael Konrad will present at the upcoming SMTA Intermountain Vendor Day and Tech Conference.

Aqueous Technologies Corporation

Ryder EMS Saves Over 20,000 Combined Tons of Water and Smog/Gas in 2014

Industry News | 2015-03-28 18:20:38.0

Ryder Industries today announced that the 2014 cleantech results have arrived!

Ryder Industries Ltd.


results of ionic contamination in water searches for Companies, Equipment, Machines, Suppliers & Information

Best SMT Reflow Oven

High Precision Fluid Dispensers
One stop service for all SMT and PCB needs

World's Best Reflow Oven Customizable for Unique Applications
SMT feeders

Software programs for SMT placement and AOI Inspection machines from CAD or Gerber.
High Throughput Reflow Oven

Component Placement 101 Training Course
SMT spare parts

500+ original new CF081CR CN081CR FEEDER in stock