Electronics Forum | Wed Feb 02 12:11:31 EST 2000 | Dave F
Casimir: Resistivity of Solvent Extract (ROSE) testers measure ionic contamination by washing boards with a DI water/IPA solution. (No-clean people: Stop and go on to something else.) The testers are process control instruments used to monitor a
Electronics Forum | Mon Jun 28 10:03:22 EDT 2004 | davef
First, welcome to your new job. Second, IPC-TM-650 2.6.14 is only loosely an �Ionic Contamination (Electromigration) Test�. * Electromigration Test, IPC TM 650 2.6.14, 2.6.14.1 * Ion Chromatography for Ionic Cleanliness, IPC TM 650 2.3.28 Third, I
Electronics Forum | Mon Jun 11 22:06:00 EDT 2001 | davef
The issue is not the cleanliness of your in-bound water. The issue is the cleanliness of the board your customer receives. Look at J-STD-001C, Para 8, "Cleanliness Requirements". The end product cleanliness is the end result of your: * In-bound
Electronics Forum | Wed Dec 09 21:45:11 EST 1998 | Dave F
Graham: I agree. Very thorny. What is clean?? And how is that controlled?? Back 25 or so years ago, soldering was done with high solids rosin fluxes. The issue with cleanliness was ionic contamination. The US military and others set a fairly a
Electronics Forum | Tue Jun 12 18:06:17 EDT 2001 | davef
The criterion you use will depend on the test method you select. For minimum requirements, look at J-STD-001C, Para 8, "Cleanliness Requirements". I figure that you�d measure the residues on a lot of your current product, measure the res on a lot o
Electronics Forum | Thu Nov 02 17:15:48 EST 2006 | Mike Konrad
Asoe, The systems you are describing are Resistivity of Solvent Extract (ROSE) Testers. These systems are available using one of two technologies, Static or Dynamic. Both systems use a calibrated test solution comprised of IPA and DI water. The t
Electronics Forum | Sun May 09 16:25:00 EDT 2004 | gabriele
Military and most commercial standards requires > post-soldered boards to measure less than 10 > �g/in of NaCl (14 when using an Omegameter, 20 > on a Ionagraph, and 37 on a Zero-Ion). > > As Dave > stated, 6.5 �g/in of NaCl is called out in >
Electronics Forum | Wed Nov 18 14:42:22 EST 1998 | Dave F
| I heard somewhere that SMEMA has joined IPC, and that the association has decided to boycott Nepcon from | year 2000. Can anyone tell me if this is true | Nick: SMEMA and IPC are talking about merging (EP&P, 11/98, p 18). Below is a news release
Electronics Forum | Tue Jan 11 09:47:01 EST 2000 | Dave F
Abbas: Sources of information on DFM/DFT are: � "SMTnet Express" articles on DFM by Earl Moon � IPC-D-279, 'Design Guidelines for Reliable Surface Mount Technology Printed Board Assemblies' � Books in SMTnet and SMTA book stores � Other examples ar