Technical Library | 2019-12-12 02:43:44.0
Today we discuss the reason that causes temperature humidity chamber to alarm,In most cases, the equipment alarm is caused by the improper operation in the process of use, which mainly includes following reasons:that are refrigeration system, temperature system and circulating system. First, Refrigeration system 1, refrigeration compressor overpressure alarm. If the refrigerant pressure exceeds the set value, it will stop and alarm at the same time. At this time, the fault must be eliminated and then manually reset. 2, short phase power supply, phase sequence alarm. When the external power supply of the equipment is out of phase or the phase sequence is changed, it will stop and alarm at the same time. 3. The circulating cooling water is short of water to alarm. When the water pressure of the cooling circulating water system is insufficient, it will stop and alarm at the same time, and it must wait for the fault to be eliminated and reset at the same time before it could run normally. 4, refrigeration compressor overheating alarm. When the coil of the compressor is overheated and the power supply of the line is not normal, it will stop and alarm at the same time. Second, Temperature system 1, the overtemperature alarm in the chamber. The sensors in the channel and the sample area are equipped with overtemperature protection devices, and there are also overtemperature protecter on the control panel. When the temperature in the working chamber exceeds the setting value on the controller, it will stop and alarm. 2. sample overtemperature protection. When the temperature in the sample area exceeds the protection temperature set by the controller, it will stop and alarm at the same time. The overtemperature protection of the sample is divided into upper limit protection and lower limit protection, which can be set according to the demand, Third,Circulating system 1. The alarm is caused by the overheating of the circulating fan. When the coil of the fan is over-heated, the alarm will be stopped at the same time. 2. The fan over-current alarm. When the current of the fan exceeds the allowable value, the alarm is stopped at the same time, and the normal operation can only be carried out after the fault maintenance of the overcurrent is completed. This is what we talk about today,if you have more questions,let us know.
New Equipment | Cable & Wire Harness Equipment
Hex head screw threaded water heater boilers NTC thermistor temperature sensor Application: NTC thermistor temperature sensor probe for temperature measurement of liquid, water, air, etc. Typical application coffee maker, tea kettle, drinking water,
Technical Library | 2019-11-12 02:09:22.0
Thermal shock test chamber can be used for testing the chemical change or physical damage on composite materials caused by the thermal expansion and contraction of the sample in the shortest time,which is subjected to extremely and continuous high and low temperature environment.so how to check the temperature recovery time of this chamber? Normally we take following steps to inspect the temepratuire recovering time: 1.Install the temperature sensor at the specified position, and adjust the temperature controller of hot zone and cold zone to the required nominal temperature respectively. 2.The temperature increases and reduces respectively,30min after temperature in two zones reach stable status,record temperature value of the measuring point,pls set the temperature value of two zones to be required nominal temperature. 3.The temperature shock test chamber automatically places the inspected load into theh ot zone,select the corresponding retention time according to regulated standard. 4.Set the transfer time,then the inspection load is transferred from hot zone to cold zone, and the temperature of the measuring point is observed and recorded, and then the reverse conversion of the load from cold zone to hot zone is carried out according to the same method, and the temperature of the measuring point is observed and recorded. www.climatechambers.com
Watlow, the global leader in designing, engineering and manufacturing electric heaters, sensors, temperature controllers, and software for many industries.
Industry Directory | Manufacturer
Stellar Technology is a sensor manufacturer company specializing in custom sensors, LVDT sensors, and pressure transducers for industrial applications.
Manufacturer of thermocouples, thermocouple wire, RTD's, temperature sensors.
Industry Directory | Distributor
W. H. Cooke & Co., Inc. - Manufacturer of Thermocouples and RTDs. Distributor of Temperature Sensors and Specialty Control Systems.
Industry Directory | Manufacturer / Manufacturer's Representative
Kingge Electronics focus on temperature sensing for over 19 years. We are the professional manufacturer integrated by designing, developing and manufacturing of NTC thermistor and temperature sensor for varies industries.
Industry Directory | Manufacturer
The Elpos Ltd. is an company that designs and manufactures industrial electronic control devices for electric heating systems. Our company is located in Croatia/EU
Industry Directory | Manufacturer
A primary source for temperature sensors. Whether you're looking for engineering expertise, RTDs, or custom design, we look forward to being your partner for all your temperature measurement needs.