Electronics Forum | Tue Dec 14 11:05:43 EST 2010 | baildl632
We just received a Paragon 150 oven for production. We hadn't used it a week and we're getting "Top Blower Fail " alarm. I have checked all the top blower fans and they all are running. Can someone help as to why we're in alarm yet all the blowers ar
Electronics Forum | Mon Dec 25 12:17:57 EST 2006 | KEN
first, does the recipe have the heat and conveyor boxes checked? If no then it does nothing. second, have you pressed the round green switch? third, are there any alarms in the alarm box? Do you have a controller link fail? Verify the cable is p
Electronics Forum | Fri Sep 08 10:23:38 EDT 2006 | slthomas
By profile (profile has not been changed) are you referring to the oven zone settings or the actual charted profile of a trip through the oven as recorded by a thermal profiler? Some ovens will continue to function without warning as long as temps
Electronics Forum | Thu Apr 24 14:07:49 EDT 2008 | slthomas
Don't know that oven or if the layout is similar at all to a Heller, but in our 1500s you could lose a blower and not get an alarm until a large board blocked vertical airflow. At that point the thermocouple in the faulty zone would then lose heat
Electronics Forum | Wed Sep 11 17:16:17 EDT 2013 | saied
Hello, We would like to order this spare-part blower motor electrovert omni Excel for Speedline Technologies Electrovert, type: Omni Excel 7 Serial: 476219 Date: 4/04 and we would be thankful if you provide us the Service manul for your prod
Electronics Forum | Mon Feb 04 10:38:14 EST 2008 | slthomas
Sure looks like flux residue to me and I don't know how your bare boards could be causing that unless there's something on them when you get them, and that you would notice. I'd still be looking at my own system, blowers and exhaust lines. Do any of
Electronics Forum | Tue Oct 09 10:18:56 EDT 2007 | lococost
We used to do this, but we dont any more. Never found something with the Mole. We have had 2 blowers come to a halt due to stuck bearings, but that was easely spotted without a check. (Temperature alarm and Huge whining noise)
Electronics Forum | Mon Sep 01 04:55:20 EDT 2008 | benefon
Hello all Our Omni 5 has given the 'Cooling module high temp' warning twice during the past month. I suspect that the blower motor is the culprit but have not been able to verify this because the oven has started up normally after acknowledging the
Electronics Forum | Mon Oct 01 19:44:49 EDT 2007 | marcelll
Just bought a used VIP 98 and I have an alarm. Computer don't communicate with the embedded controler of the oven. I've check the cabling, OK, and there's power on the controler. The PC is booting normally. The controler is plug in the serial port 2
Electronics Forum | Fri Jun 03 14:55:15 EDT 2005 | Bman
Both our Quad ZCR and our Conceptronic HVN-102 ovens have had blowers out with no alarms raised. We knew there were problems based on how boards were soldering, but don't count on your oven to tell you if anything is wrong with it. We verify once a