Full Site - : servo 20amps error (Page 14 of 23)

CP-65: Servo alarm C Axis, Servo overflow?

Electronics Forum | Tue Mar 23 18:02:54 EDT 2010 | rodrigo

Hi all, We're setting up a cp-65 and we're finding some issues with it. It has a missing 1st solenoid/switch and some nozzle valves on the cam. The biggest issue is this C axis servo error. The proper data was set to a cam speed of 250 (25%). That's

Fuji IP3 alarm x1 axis

Electronics Forum | Tue Mar 05 12:00:00 EST 2013 | aj

do you have an error alarm code on the actual servoe itself?

ALL SERVO DRIVERS DO NOT TURN ON FOR CP8-42

Electronics Forum | Thu Nov 03 13:28:48 EDT 2016 | jimmyboz

If there are no errors, check main relay contacts, it is common that one contact is not closing.

DEK 265 Horizon Servo Following Error

Electronics Forum | Fri Jan 05 11:20:31 EST 2018 | dekhead

AC2 on MUX card).

DEK 265 Horizon Servo Following Error

Electronics Forum | Fri Jan 05 12:18:10 EST 2018 | dekhead

Does it happen in board stop move in diagnostics?

DEK 265 Horizon Servo Following Error

Electronics Forum | Fri Jan 05 14:48:09 EST 2018 | ilavu

Yes.

DEK 265 Horizon Servo Following Error

Electronics Forum | Fri Jan 05 14:58:36 EST 2018 | dekhead

Information sent to your email.

Fuji CP 65 FRQ Servo Overflow

Electronics Forum | Wed Mar 07 14:55:13 EST 2018 | cyber_wolf

In my experience that error almost always indicates a bad amplifier.

Fuji IP 2 Servo NG error?

Electronics Forum | Mon Mar 09 17:42:56 EDT 2009 | smellew

ok Please power on the machine & confirmed that M1CP 2 is ok this is the breaker for the 35V & check M1cp1 now look at the drawings at address 1011 & check the axis ready relays Z1 11CS3x 151-GB Closed is ok if open see address 5402 Z1 servo amp is f

Fuji FCP 2 Check Servo issue

Electronics Forum | Tue Sep 21 18:46:24 EDT 2010 | slwolbert

Greetings: > > I am having 'Check Servo' issues > with an FCP 2 4000. It will zero set but given a > few minutes afterwards, the check servo alarm > sounds. > > At times the X/Y table will 'coast' > back to beginning position, like the power


servo 20amps error searches for Companies, Equipment, Machines, Suppliers & Information

PCB Handling with CE

World's Best Reflow Oven Customizable for Unique Applications
Online Equipment Auction of Altronic: Small-Batch Surface Mount & Assembly Facility

High Precision Fluid Dispensers
2024 Eptac IPC Certification Training Schedule

Software for SMT placement & AOI - Free Download.
PCB Depanelizers

Private label coffee for your company - your logo & message on each bag!