Electronics Forum | Tue Mar 23 18:02:54 EDT 2010 | rodrigo
Hi all, We're setting up a cp-65 and we're finding some issues with it. It has a missing 1st solenoid/switch and some nozzle valves on the cam. The biggest issue is this C axis servo error. The proper data was set to a cam speed of 250 (25%). That's
Electronics Forum | Tue Mar 05 12:00:00 EST 2013 | aj
do you have an error alarm code on the actual servoe itself?
Electronics Forum | Thu Nov 03 13:28:48 EDT 2016 | jimmyboz
If there are no errors, check main relay contacts, it is common that one contact is not closing.
Electronics Forum | Fri Jan 05 11:20:31 EST 2018 | dekhead
AC2 on MUX card).
Electronics Forum | Fri Jan 05 12:18:10 EST 2018 | dekhead
Does it happen in board stop move in diagnostics?
Electronics Forum | Fri Jan 05 14:58:36 EST 2018 | dekhead
Information sent to your email.
Electronics Forum | Wed Mar 07 14:55:13 EST 2018 | cyber_wolf
In my experience that error almost always indicates a bad amplifier.
Electronics Forum | Mon Mar 09 17:42:56 EDT 2009 | smellew
ok Please power on the machine & confirmed that M1CP 2 is ok this is the breaker for the 35V & check M1cp1 now look at the drawings at address 1011 & check the axis ready relays Z1 11CS3x 151-GB Closed is ok if open see address 5402 Z1 servo amp is f
Electronics Forum | Tue Sep 21 18:46:24 EDT 2010 | slwolbert
Greetings: > > I am having 'Check Servo' issues > with an FCP 2 4000. It will zero set but given a > few minutes afterwards, the check servo alarm > sounds. > > At times the X/Y table will 'coast' > back to beginning position, like the power