Full Site - : siemens simplace 80 s20 (Page 8 of 12)

Siemens 80 S-20 problem

Electronics Forum | Sat Mar 03 10:42:49 EST 2007 | chrisgriffin

No. The Sitest button is greyed out. Can I install a regular windows version of NT 4.0, or does it have to be a Siemens version of windows?

Siemens 80 S-20 problem

Electronics Forum | Thu Feb 22 14:41:31 EST 2007 | Tom B

Chris, It's been a while since I used a Siemens, but I was thinking its starting communication to Gantries, tables, and WPC for Axis zeroing. Like I said its been awhile! When replacing drive, did you copy the *.ma files back to the drive? Tom

Siemens 80 S-20 problem

Electronics Forum | Fri Feb 23 09:29:59 EST 2007 | chrisgriffin

I did restore the .ma files, and yes, the computer does communicate with the gantries for zeroing. But the machine is still hung on "initializing machine". It never asks me to push the start button. It is like it is trying to collect necessary dat

Siemens 80 S-20 problem

Electronics Forum | Tue Mar 13 02:12:04 EDT 2007 | (- -")

You have to install the RMOS to MC's HDD. The RMOS Version must match with the station software. After Install RMOS you have to perform machine distribution.

Siemens 80 S-20 problem

Electronics Forum | Tue Mar 13 13:06:49 EDT 2007 | tommyttr

I think it is in the ideal.ma or actual.ma file. You could also use the first RMOS boot disk. This will ask you for it there.

Siemens 80 S-20 problem

Electronics Forum | Wed Feb 21 14:56:09 EST 2007 | chrisgriffin

I just had to replace the hard drive in the SC and the MC. I partitiones the MC drive and installed all operating systems. The machine boots up and gets past "software booting", "conversion of machine data", and then hangs on "initializing machine"

Siemens 80 S-20 problem

Electronics Forum | Thu Mar 08 04:54:05 EST 2007 | stimpk

ON the older S15's you booted Stest from a floppy. On newer machines you have the capabilities to switching to Stest without rebooting, Although you must be logged in as admin/Service Engineer. Thats why your button is greyed out. Try logging on in s

Siemens 80 S-20 problem

Electronics Forum | Tue Mar 13 10:17:49 EDT 2007 | chrisgriffin

Thanks for all the help. I have decided to clone the 2 hard drives from my good machine and put them in the broken machine. That will get my machine running but the 2 machines will be addressed the same. Does anyone know what files to change to re

Siemens 80 S-20 problem

Electronics Forum | Thu Mar 08 06:30:48 EST 2007 | tommyttr

Chris, The machine is looking for a response from the LC. Usually, it will hang up from a corrupted .gf file. delete all the .gf files from the station. make sure you are NOT hooked up to the LC and/or LC turned off, put machine in stand alone mode.

Siemens SiPlace, Model 80 S20 FS02

Electronics Forum | Fri Jul 28 09:35:12 EDT 2006 | chrisgriffin

I think Siemens 80 S20 is a great machine. I worked on them for a few years, with very little problems. They are extremely easy to maintain. I think a complete PM took about an hour. The software is good and user friendly. You can change one over


siemens simplace 80 s20 searches for Companies, Equipment, Machines, Suppliers & Information