Electronics Forum | Tue Mar 25 15:16:16 EDT 2014 | yuran111
machine controller BIOS loads only cyclically until pressed reset button on it - now checks the configuration and loading tasks load. hard drive I can take from the controller Siemens s27 example? motherboard came from s27 machine, and the same softw
Electronics Forum | Mon Apr 18 18:23:41 EDT 2022 | youngbuck
Hello everyone, We have a Siemens HS50 error going on as soon as we boot up. It shows message saying "Machine is in test mode." Cause: Initalizing gantry axes. Start Sitest and check machine (firmwre versions,configuration, etc. It will try to refere
Electronics Forum | Wed Jan 27 10:03:39 EST 2016 | mjscottinnc
Through trail and error we figured that out the Ethernet connections from the MC to SC. We have gotten past the Software booting wait and are now waiting to connect to Siplace Pro. The machine came with no documentation other then what the service te
Electronics Forum | Mon Feb 01 04:57:08 EST 2016 | oxygensmd
If you can use the standalone mode then choose the program on "option" and somewhere you can load program - "aktuell". The "aktuell" program is the last program what was downloaded on this machine. In SiTest you can test and calibrate the machine. Y
Electronics Forum | Sun Dec 05 17:19:38 EST 2021 | oxygensmd
Szia! Ez nem egyike az aukciós gépeknek Hatvanból? Tápegységek mindkét oldalt jók? iCOS PC és MC PC biztosan működik? Minden kártya működik, nem ment ki vmelyiken a biztonsági zener (18V), mert táp alatt ki volt húzva, majd visszadugva? Minden tenge