Electronics Forum | Mon Mar 28 19:58:26 EST 2005 | davef
We agree with Ken. What does your field meter tell you? Taking it a step further [erzit backward?], what is it about the measurement that requires the granite surface? Wouldn't an ESD protected bench top be as flat as needed for most gauging like
Electronics Forum | Wed May 31 23:37:37 EDT 2006 | jacksaria
Hello EC, Thank you very much for the good input. I really appreciated. Our mounnters is Panasonic CM402,CM301. Do you have any suggestions/procedure how to reduce the sources of variance at each step of component placement process? regards,
Electronics Forum | Mon Sep 12 09:26:00 EDT 2016 | awhite
Our MPM Up2000 HIE is having a communication problem with any upstream machine we place in front of it...i.e. conveyor, board loader, etc. It all started when we removed a conveyor from inbetween it and a board loader, and hooked those machines up di
Electronics Forum | Thu Oct 14 18:17:34 EDT 1999 | JAX
Larry, What's happening. You can get this information from the manufacturer. All you need is the manufacturing part number. You should be able to get this from the purchasing department. Once you have this info just open up their website and fo
Electronics Forum | Mon Oct 15 11:03:24 EDT 2001 | mikecampbell
Dave, Thanks for the info! Yes, I have read the IBM document and realized that I was missinformed about the paste volume. I need 5000 to 5600 cubic mils of paste. Running the numbers I get a 32 mil aperture with a 7 mil step (the rest of the board
Electronics Forum | Wed May 31 21:33:52 EDT 2006 | jacksaria
Hello jbrower, Thank you for the feedback. Actually, our main problems is the pick and throw. Whats your suggestion how to control the pick and throw?What are the factors that affecting pick and throw?How to reduce the sources of variance at each st
Electronics Forum | Tue Mar 04 16:50:56 EST 2003 | msivigny
Hello Rohan, this is starting to date nearly 6 years ago but I will remember everything I can, we used a custom interface to input data and everything was stored in a very large database on a specific server only for quality data, I think we used Ora
Electronics Forum | Fri Aug 18 11:01:52 EDT 2006 | Frank R.
Hi, We have two complete SMT line and in this department we use conveyors for board manipulation. Concerning the wave area we are not full efficiency and I have to look for conveyors and bar code reader to make board manipulation an automatic proces
Electronics Forum | Wed Aug 07 16:49:15 EDT 2013 | hegemon
You mean you don't pull all of your thermocouples out of the ovens once a year and send them out for calibration? - lol Tough question. You have a calibrated datalogger. (I assume) You have an oven with preset zone temps, each zone controlled by a
Electronics Forum | Wed Mar 05 12:23:31 EST 2003 | msivigny
Hello Phil, We did use an Oracle relational database with an Access front end to input and query data from the system for reports. We did not perform SPC with the Oracle dB. As the whole data collection process was completely customized, we hadn't im