Full Site - : solder joint inspection mirtec (Page 18 of 254)

Ball Grid Array (BGA) Voiding Affecting Functionality

Technical Library | 2020-11-09 16:59:53.0

A customer contacted ACI Technologies regarding a high failure rate of their assemblies. They provided assemblies to be X-rayed and inspected for the purpose of identifying any process related issues such as (but not limited to) solder and assembly workmanship and evidence of damage due to moisture related problems during reflow (a.k.a. "popcorning"). Moisture damage usually appears as physical damage to the component. The first indication of moisture damage would be externally observable changes to the package in the form of bulging or fractures to the outer surface of the component, an example of which is shown in Figure 1. Internally observable indicators of moisture damage typically include fractures to the die inside the package and lifted or fractured wire bonds. These conditions would be apparent during transmissive X-ray inspection. Another symptom of moisture related damage would be inconsistent solder joint sizes that result from package deformation during the liquidus phase of the reflow process. None of these indicators of moisture related damage were present on the customer samples.

ACI Technologies, Inc.

Investigation of Through-Hole Capacitor Parts Failures Following Vibration and Stress Testing

Technical Library | 2019-06-21 10:39:15.0

Recently, an ACI Technologies (ACI) customer called to discuss failures that they had observed with some through-hole capacitor parts. The components were experiencing failures following vibration and accelerated stress testing. Upon receipt of the samples, ACI performed three levels of inspection and Energy Dispersive Spectroscopy (EDS) testing to investigate the root cause of the failures. These analyses enabled ACI to verify the elements comprising the solder joints and make the following recommendations in order to prevent future occurrences. The first inspection was to investigate the capacitor leads using optical microscopy, and no anomalies were found that could indicate bad parts from the vendor or improper handling prior to assembly. However, vertical fill in the barrel of the plated through-holes was too close to the IPC-A-610 minimum specification of 75% to determine a pass/fail condition, and therefore required further investigation.

ACI Technologies, Inc.

DIP Double-side Camera Online AOI Machine ETA-V5300

DIP Double-side Camera Online AOI Machine ETA-V5300

Videos

DIP Double-side Camera Online AOI Machine ETA-V5300​ If you could not find any similar items you want, you may send some photos to us. because our catalog and website haven't included all of our products. solder paste inspection,SMT SPI,SPI mac

Dongguan Intercontinental Technology Co., Ltd.

Online AOI Machine

Online AOI Machine

Videos

ETA DIP Inverted Camera Online AOI Machine ETA-V5200 ​ If you could not find any similar items you want, you may send some photos to us. because our catalog and website haven't included all of our products. solder paste inspection,SMT SPI,SPI m

Dongguan Intercontinental Technology Co., Ltd.

BGA & Area Array Failures, Causes & Corrective Actions Online Webinar

Events Calendar | Mon Mar 16 00:00:00 EDT 2020 - Mon Mar 16 00:00:00 EDT 2020 | ,

BGA & Area Array Failures, Causes & Corrective Actions Online Webinar

Surface Mount Technology Association (SMTA)

SMTA China East Conference 2018

Events Calendar | Mon Apr 23 00:00:00 EDT 2018 - Thu Apr 26 00:00:00 EDT 2018 | Shanghai, China

SMTA China East Conference 2018

Surface Mount Technology Association (SMTA)

A Non-destructive Approach to Identify Intermittent Failure Locations on Printed Circuit Cards (PCC) that have been Temperature Cycle Tested

Technical Library | 2020-12-07 15:26:06.0

Temperature cycling testing is a method of accelerated life testing done to PCCs that are exposed to normal operation temperature variations over its lifetime. During the testing, intermittent "open" failures can first occur at the hot and cold extremes of the test, exposing weaknesses in the design and assembly. A poor/weak solder joint fatigues, a via trace or barrel cracks, loose connections or a component fails all causing an intermittent open. When not at extreme temperatures, the PCC assembly relaxes, the "open" closes creating electrical connectivity. If you are monitoring the PCC under test in-situ you will know that an intermittent failure has occurred, and the test could be stopped for inspection. If in-situ monitoring was not implemented, you would not know if there were intermittent failures or not. The PCC gets powered up and works fine at room temperature.

ACI Technologies, Inc.

Solder Techniques for Electronic Assemblies

Training Courses | | | PCB Rework and Hand Soldering Courses

The PCB rework and hand soldering courses courses cover techniques of rework and repair of PCBs, BGAs and other electronics assemblies, and teach fundamentals of soldering of electronics assemblies.

ACI Technologies, Inc.

PCB cutting machine|PCB depaneling machine equipment

PCB cutting machine|PCB depaneling machine equipment

New Equipment | Depaneling

PCB separator used for depaneling PCB that from FR4 and aluminium material circle blade PCB cutting machine and PCB separator from ASCEN pcb depaneling equipment factory ASCEN technology as the PCB separator manufacturer provide all kinds of PC

ASCEN Technology

Hand Solder Rev 8 Certification Course

Training Courses | | | PCB Rework and Hand Soldering Courses

The PCB rework and hand soldering courses courses cover techniques of rework and repair of PCBs, BGAs and other electronics assemblies, and teach fundamentals of soldering of electronics assemblies.

EPTAC Corporation


solder joint inspection mirtec searches for Companies, Equipment, Machines, Suppliers & Information

INSPECTION TECH
INSPECTION TECH

Our Company handle AOI (Auto Optical Inspection) and SPI (Solder Paste Inspection) Machines.

Equipment Dealer / Broker / Auctions

Hwaseong-si, Gyeonggi-do, Korea
Hwaseong-si, South Korea

Phone: +82-1029254936