OEM Manufacturer for Automotive electronics such as Digital Clock, Vehicle Control Monitoring, Vehicle Timers, Alarm Security System, Immobilliser, Flashing Unit, Switch Assembly etc.
Industry Directory | Consultant / Service Provider / Manufacturer
We design and manufacture Electronic Equipment and boards. We have several divisions, among them; appliance controls, consumer products, transport (bus and trains controls), dataloggers, etc.
A500, A600, A800 - 5, 6 or 8 top/bottom cooling zones. Heating System: Up to eight groups of top and bottom forced hot air convection heating zones. Patented heating plates in each zone uniformly transfer heat to the PCBs using forced hot air co
S8, S10, S12 - 8, 10 or 12 top/bottom cooling zones. Heating System: Up to twelve groups of top and bottom forced hot air convection heating zones. Patented heating plates in each zone uniformly transfer heat to the PCBs using forced hot air con
Electronics Forum | Mon Aug 31 11:52:28 EDT 2020 | inspiredmorris20
Hello Jon, I appreciate your reply, correct there are 2 red (24v) that control the main power and 2 blue (they control the power to the units operation keys ready, start, stop, reset, change feeders.) additionally there is a red jumper wire on the E
Electronics Forum | Fri Aug 28 17:47:59 EDT 2020 | inspiredmorris20
thanks Stephen!! I'm testing for voltage and have found 24v going through the E-stop to the main switch. If i trip the E-stop i can disengage the main switch. I have no more control to the hardware then that. The software is not throwing any code ot
Used SMT Equipment | Conveyors
Details: • FIFO/LIFO • 30 slots • Input and Output conveyors • Motorized width adjustment • Programmable digital interface • SMEMA compliant • EPO Emergency stop button Condition: Complete & Operat
Used SMT Equipment | Board Cleaners
• Vintage 2008 • PLC based Control System • 480V AC 60Hz • Auto Stop/Stand by Mode • Final Rinse low flow sensor and alarm • Mach II Drying System • 2 upper, 2 lower jet manifolds • 15 HP blower upgrade • 18” Off Load Extension • Integrated
Industry News | 2003-02-07 09:13:12.0
The Sessions Covered Current and Emerging Technologies
Industry News | 2003-04-07 10:16:38.0
Portable Products and Optoelectronic Applications Still Hold Promise for Growth
Parts & Supplies | SMT Equipment
Description: DEK emergency stop switch SWITCH ^ SAFETY ^ OMRON ESTOP ^ BOM ^ (TXT) Part NO.: (195194/E0057) Product Number: SMT-D00026 Kindly contact me if you are interested. Email: alice@ksunsmt.com Skype: alice@ksunsmt.com Whats app: +86
Parts & Supplies | Screen Printers
Description: DEK emergency stop switch SWITCH ^ SAFETY ^ OMRON ESTOP ^ BOM ^ (TXT) Part NO.: (195194/E0057) Product Number: SMT-D00026
Technical Library | 2019-12-12 02:43:44.0
Today we discuss the reason that causes temperature humidity chamber to alarm,In most cases, the equipment alarm is caused by the improper operation in the process of use, which mainly includes following reasons:that are refrigeration system, temperature system and circulating system. First, Refrigeration system 1, refrigeration compressor overpressure alarm. If the refrigerant pressure exceeds the set value, it will stop and alarm at the same time. At this time, the fault must be eliminated and then manually reset. 2, short phase power supply, phase sequence alarm. When the external power supply of the equipment is out of phase or the phase sequence is changed, it will stop and alarm at the same time. 3. The circulating cooling water is short of water to alarm. When the water pressure of the cooling circulating water system is insufficient, it will stop and alarm at the same time, and it must wait for the fault to be eliminated and reset at the same time before it could run normally. 4, refrigeration compressor overheating alarm. When the coil of the compressor is overheated and the power supply of the line is not normal, it will stop and alarm at the same time. Second, Temperature system 1, the overtemperature alarm in the chamber. The sensors in the channel and the sample area are equipped with overtemperature protection devices, and there are also overtemperature protecter on the control panel. When the temperature in the working chamber exceeds the setting value on the controller, it will stop and alarm. 2. sample overtemperature protection. When the temperature in the sample area exceeds the protection temperature set by the controller, it will stop and alarm at the same time. The overtemperature protection of the sample is divided into upper limit protection and lower limit protection, which can be set according to the demand, Third,Circulating system 1. The alarm is caused by the overheating of the circulating fan. When the coil of the fan is over-heated, the alarm will be stopped at the same time. 2. The fan over-current alarm. When the current of the fan exceeds the allowable value, the alarm is stopped at the same time, and the normal operation can only be carried out after the fault maintenance of the overcurrent is completed. This is what we talk about today,if you have more questions,let us know.
Flexible PCB Board Cutting Machine PCB Punching Machine With Cutomized Die Tooling PCB Punching Machine Features: 1. Depaneling PCB/FPC by means of punching dies, to avoid micro-cracks caused by manual. 2. Die toolings is changeable 3. Easy set
A500, A600, A800 - 5, 6 or 8 top/bottom cooling zones. Heating System: Up to eight groups of top and bottom forced hot air convection heating zones. Patented heating plates in each zone uniformly transfer heat to the PCBs using forced hot air co
Career Center | 10th of ramadan, Egypt | Engineering,Maintenance,Management,Production
• Excellent Analytical, inter-personal and communication skills • Ability to work effectively in teamwork • Ability to set and achieve goals and work under pressure • Learn quickly, hard worker • Capable of study and research acti
Career Center | TRIVANDRUM, kerala India | Engineering,Maintenance,Research and Development
System Integration, Software Configuration Project Implementation & Commissioning Installation and Servicing of CCTV,Access Control,Public Address systems, Fire & Alarm Security System, Biometric Attendance System. Language Skills-C, C++,UNIX,LIN
KingFei SMT Tech | https://www.smtspare-parts.com/sale-40318991-n510041345aa-panasonic-npm-push-button-switch-emergency-safety-stop-switch.html
N510041345AA Panasonic NPM Push Button Switch Emergency Safety Stop Switch Leave a Message We will call you back soon! Your message must be between 20-3,000 characters
Lewis & Clark | https://www.lewis-clark.com/product/mydata-l-049-0085-trackball-with-emergency-stop/
Mydata L-049-0085 Trackball with Emergency Stop - Lewis and Clark, Inc. Skip to content My Cart: $ 0.00 0 View Cart Checkout No products in the cart. Subtotal