Full Site - : stop gsm (Page 5 of 10)

GSM machine stops randomly; "BM" bus master light out

Electronics Forum | Fri Sep 27 15:14:04 EDT 2019 | dilogic

Just one more thought - we had an issue with +12V supply for VME rack. One tantalum cap in the DC/DC converter module for linear encoder interpolator shorted it out, but oddly enough - not always. We ended up hooking scope to all PSU voltages and whe

GSM machine stops randomly; "BM" bus master light out

Electronics Forum | Wed Nov 27 08:54:03 EST 2019 | ttheis

Hi Tushar, Thanks for the reply. I do believe I put it into debug mode but I will be sure to check next time I try logicomm. I am not using any RAMTF or PTF. At the moment I have upgraded the machine from EPC-5 to EPC-5-66 which I found cheap. The

GSM machine stops randomly; "BM&amp

Electronics Forum | Fri Jan 29 13:25:43 EST 2021 | ttheis

Update: I have replaced both dc-dc converters without any improvement. Observing the issue again yesterday I was able to see more of the problem. Logicomm reported a bus error at fcff1043 running "butt" (photo attached.) The DC power ligh

Universal GSM Placement speed

Electronics Forum | Fri Apr 05 18:33:31 EDT 2019 | ttheis

I am also interested in this but to slow one of our machines down- it stops too quickly and shakes the machine more than I would like. We are running GSM1's on OS/2 and uic sw 3.3.

SMT EQUIPMENT FOR LOW VOLUME HIGH MIX

Electronics Forum | Mon Apr 28 12:29:23 EDT 2003 | hruiz

Hi Jax, I�ve took times, and average, we last from 25 to 40 minutes to load a CP6 depending on how big is the load, but quality guys last other 25 min. per equipment to audit, we usually have 2 CP6 and 1 GSM or 1 CP6 and 2 GSM, at any case, we need t

GSM machine stops randomly; "BM" bus master light out

Electronics Forum | Wed Dec 23 12:24:37 EST 2020 | ilavu

1. Palm down the GSM and open the safety cover to check input voltage +12VDC (at KDC2 3PL pins 2 to 3) and output voltage +5VDC (at KDC2 2PL pin 4 to 3) at the DC/DC converter. The DC/DC converter is located inside the control panel assembly ("Nose c

GSM1 occasional fault

Electronics Forum | Tue Jan 26 05:42:56 EST 2010 | dilogic

Our GSM1 with Flex2 heads started to generate occasional error message: "Axis head 1 theta positive lead error during move absolute command" and then stop. After palm-down it runs again for some time. Everything looks fine, so I have no idea where

Axis head 2 z velocity error

Electronics Forum | Mon Jan 15 11:12:08 EST 2007 | jaimebc

I've had experienced this issues here with our GSM's Flex heads. Try this: 1.- Clean your linear scales with alcohol and a lint free cloth. Both the X and Y. This one has fixed the majority of our errors when one of the heads just stops for no apare

GSM1 Y Axis Limit Switch

Electronics Forum | Fri Apr 28 16:03:31 EDT 2017 | ilavu

I have GSM1 (OS/2) machine and it does not zero. The Y axis comes to all the way front to hard stop. I replaced the limit switch before the hard stop and can not find any way to test the signal from limit switch in diagnostic. I like to replace the c

GSM2 spindles Not seen for head

Electronics Forum | Tue Sep 29 09:39:02 EDT 2015 | rgduval

Hey, David, For service, check out 4TechUSA over in Detroit. It's not Chicago, but, you're closer to Detroit up there than I am down here in Houston :) For your issue....do you have access to the UIC Knowledge Base? The first issue I found in the


stop gsm searches for Companies, Equipment, Machines, Suppliers & Information

2024 Eptac IPC Certification Training Schedule

High Throughput Reflow Oven
See Your 2024 IPC Certification Training Schedule for Eptac

World's Best Reflow Oven Customizable for Unique Applications
Circuit Board, PCB Assembly & electronics manufacturing service provider

High Precision Fluid Dispensers
Void Free Reflow Soldering

Training online, at your facility, or at one of our worldwide training centers"