Electronics Forum | Mon Apr 28 12:29:23 EDT 2003 | hruiz
Hi Jax, I�ve took times, and average, we last from 25 to 40 minutes to load a CP6 depending on how big is the load, but quality guys last other 25 min. per equipment to audit, we usually have 2 CP6 and 1 GSM or 1 CP6 and 2 GSM, at any case, we need t
Electronics Forum | Wed Dec 23 12:24:37 EST 2020 | ilavu
1. Palm down the GSM and open the safety cover to check input voltage +12VDC (at KDC2 3PL pins 2 to 3) and output voltage +5VDC (at KDC2 2PL pin 4 to 3) at the DC/DC converter. The DC/DC converter is located inside the control panel assembly ("Nose c
Electronics Forum | Tue Jan 26 05:42:56 EST 2010 | dilogic
Our GSM1 with Flex2 heads started to generate occasional error message: "Axis head 1 theta positive lead error during move absolute command" and then stop. After palm-down it runs again for some time. Everything looks fine, so I have no idea where
Electronics Forum | Mon Jan 15 11:12:08 EST 2007 | jaimebc
I've had experienced this issues here with our GSM's Flex heads. Try this: 1.- Clean your linear scales with alcohol and a lint free cloth. Both the X and Y. This one has fixed the majority of our errors when one of the heads just stops for no apare
Electronics Forum | Fri Apr 28 16:03:31 EDT 2017 | ilavu
I have GSM1 (OS/2) machine and it does not zero. The Y axis comes to all the way front to hard stop. I replaced the limit switch before the hard stop and can not find any way to test the signal from limit switch in diagnostic. I like to replace the c
Electronics Forum | Tue Sep 29 09:39:02 EDT 2015 | rgduval
Hey, David, For service, check out 4TechUSA over in Detroit. It's not Chicago, but, you're closer to Detroit up there than I am down here in Houston :) For your issue....do you have access to the UIC Knowledge Base? The first issue I found in the
Electronics Forum | Thu Feb 04 03:54:46 EST 2010 | mika
Hi, I know that I been out for this exact error message before (several years ago) and I am just thinking about it. It was something simple... Ok. When You say stops in the middle of placement phase; Do you mean in the first task block, have it alre
Electronics Forum | Fri Mar 18 08:50:21 EST 2005 | Bored
I usually delete segment repair files 'segrep' monthly without implications. It speeds the machine up when generating other segrep files. I believe it is just an archive for e-stop generated production files and has no bearing on management data. Hop
Electronics Forum | Mon Mar 21 21:38:40 EST 2005 | pmd
You do not need to back up segrep. This is only used for boards currently on the machine whenever the machine encounters a palm down or soft stop. It only contains what is mounted and or not mounted on that board. No System infomation is contained in
Electronics Forum | Fri Oct 26 13:43:54 EDT 2012 | whispell
Make sure your machine configuration is correct. You may have something assigned to the machine that is no longer there. For 24V check to make sure all of the E-stop jumpers are plugged in.