Electronics Forum | Mon Apr 28 12:29:23 EDT 2003 | hruiz

Hi Jax, I�ve took times, and average, we last from 25 to 40 minutes to load a CP6 depending on how big is the load, but quality guys last other 25 min. per equipment to audit, we usually have 2 CP6 and 1 GSM or 1 CP6 and 2 GSM, at any case, we need t

GSM machine stops randomly; "BM" bus master light out

Electronics Forum | Wed Dec 23 12:24:37 EST 2020 | ilavu

1. Palm down the GSM and open the safety cover to check input voltage +12VDC (at KDC2 3PL pins 2 to 3) and output voltage +5VDC (at KDC2 2PL pin 4 to 3) at the DC/DC converter. The DC/DC converter is located inside the control panel assembly ("Nose c

GSM1 occasional fault

Electronics Forum | Tue Jan 26 05:42:56 EST 2010 | dilogic

Our GSM1 with Flex2 heads started to generate occasional error message: "Axis head 1 theta positive lead error during move absolute command" and then stop. After palm-down it runs again for some time. Everything looks fine, so I have no idea where

Axis head 2 z velocity error

Electronics Forum | Mon Jan 15 11:12:08 EST 2007 | jaimebc

I've had experienced this issues here with our GSM's Flex heads. Try this: 1.- Clean your linear scales with alcohol and a lint free cloth. Both the X and Y. This one has fixed the majority of our errors when one of the heads just stops for no apare

GSM1 Y Axis Limit Switch

Electronics Forum | Fri Apr 28 16:03:31 EDT 2017 | ilavu

I have GSM1 (OS/2) machine and it does not zero. The Y axis comes to all the way front to hard stop. I replaced the limit switch before the hard stop and can not find any way to test the signal from limit switch in diagnostic. I like to replace the c

GSM2 spindles Not seen for head

Electronics Forum | Tue Sep 29 09:39:02 EDT 2015 | rgduval

Hey, David, For service, check out 4TechUSA over in Detroit. It's not Chicago, but, you're closer to Detroit up there than I am down here in Houston :) For your issue....do you have access to the UIC Knowledge Base? The first issue I found in the

GSM1 occasional fault

Electronics Forum | Thu Feb 04 03:54:46 EST 2010 | mika

Hi, I know that I been out for this exact error message before (several years ago) and I am just thinking about it. It was something simple... Ok. When You say stops in the middle of placement phase; Do you mean in the first task block, have it alre

Backing up GSM - Segment Repair importance...

Electronics Forum | Fri Mar 18 08:50:21 EST 2005 | Bored

I usually delete segment repair files 'segrep' monthly without implications. It speeds the machine up when generating other segrep files. I believe it is just an archive for e-stop generated production files and has no bearing on management data. Hop

Backing up GSM - Segment Repair importance...

Electronics Forum | Mon Mar 21 21:38:40 EST 2005 | pmd

You do not need to back up segrep. This is only used for boards currently on the machine whenever the machine encounters a palm down or soft stop. It only contains what is mounted and or not mounted on that board. No System infomation is contained in

GSM2 Universal user name and password

Electronics Forum | Fri Oct 26 13:43:54 EDT 2012 | whispell

Make sure your machine configuration is correct. You may have something assigned to the machine that is no longer there. For 24V check to make sure all of the E-stop jumpers are plugged in.