New Equipment | Wave Soldering
Stand-alone - matches well with any existing wave solder Minimum flux residue by: Minimal spray pressure Optimum distance from nozzle to PCB Edge-off (Pat. pending) feature Ease of Operation - Touch panel D
Adjustable air blow speed Heater Temp ≅ Blow Air Temp Profile Temp ≅ Setting Temp Best At performance in its class Lowest run cost in its class Windows XP software operation Lead-free reflow HAT profile optimization High v
Career Center | lagos, Nigeria | Maintenance
CHEVRON OIL AND GAS LIMITED NO 8 MACARTH STREET VICTORIA ISLAND LAGOS/NIGERIA CHEVRON OIL AND GAS LIMITED intends to Invite experienced and reputable persons having prime experience and capable of providing services of a plumber(as individuals or
Electronics Forum | Tue Oct 01 14:53:24 EDT 2013 | felo188
it's means that a pcb part responsible for second top zone is broken. To make sure i changed second thermocouple and heater with first. Now there is no overshoot. But I have still problem with automatically shutdown. It is turning off after 1 or 2
Electronics Forum | Thu Feb 16 20:55:57 EST 2017 | youngbuck
Was wondering if anybody has experience a zone that will not get up to temperature. I changed the Solid state relay, made sure the thermocouple is working. The only thing I can think of is the bottom heater panel has a corroded/broken wire which is a
Electronics Forum | Mon Jan 20 11:11:24 EST 2014 | fnorradd
I have an Ersa Versaflow selective solder machine (single bath) which runs via a Profibus control system. I have checked all of the settings on the inverter, and all of the connections and outputs throughout the machine, but the machine returns a 68
Electronics Forum | Mon Feb 10 17:04:35 EST 2014 | globalpowerproducts
I am having a problem producing clean boards when i run them through my new machine. Currently i use an Electrovert system that uses trays and we are trying to upgrade our equipment so I bought a SHEO 8250 and it is making the boards dirty and lots o
Electronics Forum | Fri Aug 13 07:11:12 EDT 1999 | Earl Moon
Ladies and Gentlemen, As a newly appointed DFM/CE "guru" here, one of my responsibilities has become repair (of course). As I have some knowledge of BGA repair/rework using semi-automated equipment, it naturally follows I would hav tremendous insigh
Electronics Forum | Fri Aug 13 08:14:38 EDT 1999 | Peter Barton
| Ladies and Gentlemen, | | As a newly appointed DFM/CE "guru" here, one of my responsibilities has become repair (of course). As I have some knowledge of BGA repair/rework using semi-automated equipment, it naturally follows I would hav tremendous