phoenix|x-ray manufactures microfocus X-ray systems and provides system maintenance plus inspection services. Systems come with an open or closed tube and are dedicated to the pcba, package and multilayer industries.
Industry Directory | Consultant / Service Provider
Non-desctructive 2D and 3D digital X-Ray and Computed Tomography (CT) inspection lab. Our imagery provides detailed insight down to single micron resolution for PCBs and internal views of full multi-material assemblies.
GE's phoenix nanotom® s is the first 180 kV/15 W nanofocus computed tomography (nano ct) system perfectly tailored to applications e.g. in material science, precision injection moulding or micromechanics. The nanotom® is the inspection solution for
Qualitel highly recommends that all products be fully tested. Qualitel can provide the following test services for our customers: Flying Probe Testing - Qualitel has full flying probe capability to provide fixtureless ICT testing with 85-99% test
Electronics Forum | Mon Jun 18 15:42:32 EDT 2001 | Gil Zweig
Transmission x-ray inspection is the technique most people are familiar with. Since materials will absorb or transmit x-rays as a function of their atomic number and thickness, the transmission x-ray image provides a two dimensional represenation of
Electronics Forum | Mon Feb 24 20:37:01 EST 2003 | davef
Key Food and Drug Administration [FDA] Compliance Guidelines are in: * Blood/Biotechnology * Cosmetics * Drugs * Food * Medical Devices * Positron Emission Tomography The medical device industry adheres to the rules of Good Manufacturing Practice (G
Used SMT Equipment | X-Ray Inspection
Viscom x-ray inspection Highlights •2D and 3D X-ray inspection without mechanical conversion •Designed for larger, heavier inspection objects •Precision manipulation system with up to 8 CNC-capable axes •High magnification with angled radiation
Industry News | 2018-04-11 20:04:01.0
SMTA Europe announces Session 3 Technical Program on Advanced Test Methods at the “Electronics in Harsh Environments Conference” to be held in Amsterdam, Netherlands, on April 25th, 2018.
Industry News | 2022-01-29 14:38:47.0
At the 65th IPC Annual Meeting on January 25, held in conjunction with IPC APEX EXPO 2022, the IPC Board of Directors announced new officers and members. Board officers serve a two-year term; board members serve a four-year term, and student board member serves a one-year term.
Technical Library | 2021-03-18 20:07:08.0
X-ray tomography is a promising technique that can provide micron level, internal structure, and three dimensional (3D) information of an integrated circuit (IC) component without the need for serial sectioning or decapsulation. This is especially useful for counterfeit IC detection as demonstrated by recent work. Although the components remain physically intact during tomography, the effect of radiation on the electrical functionality is not yet fully investigated. In this paper we analyze the impact of X-ray tomography on the reliability of ICs with different fabrication technologies.
Technical Library | 2023-11-20 17:30:11.0
Summary for today 1. Electronic component inspection and failure analysis. 2. Component counting and material management. 3. Reverse engineering. 4. Counterfeit detection. 5. Real-time defect verification. 6. Computed tomography (CT) techniques and how to differentiate between 2D, 2.5D, and 3D x-ray inspection. 7. Design for manufacturing (DFM) and design for x-ray inspection (DFXI). 8. Voids, bridging, and head-in-pillow failures in bottom terminated components (BTC). 9. Artificial Intelligence and x-ray inspection
We stopped by ifixit for a chat about our new TruView Fusion CT - our 3D X-Ray system. And of course, we did a virtual teardown of the Apple AirPod, because we just can't help ourselves...
The new Jade FP is launched into an aggressive market sector where both value and performance must be met, an area in which Nordson DAGE already has a market-leading reputation. "Performance Beyond Expectations" is this exciting new system's slogan
Events Calendar | Thu Apr 22 00:00:00 EDT 2021 - Thu Apr 22 00:00:00 EDT 2021 | ,
Ohio Chapter Meeting: Industry 4.0 / Non-Destructive Failure Analysis
Events Calendar | Mon Apr 23 00:00:00 EDT 2018 - Thu Apr 26 00:00:00 EDT 2018 | Shanghai, China
SMTA China East Conference 2018
Career Center | Woodbury, Minnesota USA | Management,Production
Over 20 yrs experience in SMT. Worked with medical, industrial, communications, aerospace and automotive electronics. Have experience working in ITAR controlled companies.
Lewis & Clark | http://www.lewis-clark.com/product-tag/ge-nanotom-computed-tomography-xray/
GE Nanotom Computed Tomography Xray Archives - Lewis and Clark Skip to content My Cart: 0 View Cart Checkout No products in the cart. Subtotal
Surface Mount Technology Association (SMTA) | https://www.smta.org/knowledge/proceedings_abstract.cfm?PROC_ID=4996
. Solder voids were analyzed by computed tomography (CT), and methods were developed to implement the voids from CT into FEM simulation models