Electronics Forum | Tue Jun 17 10:46:16 EDT 2014 | bestglobalsmt
When the machine loads up it gets to the 2nd to last step where it starts to load vacuum data - we get 4 pop up windows once that fails. Ea2510 Machine Start error - Machine cannot be started Es00212 APPL CPU Haandshake error Ea2504 I/O Data trans
Electronics Forum | Tue Feb 09 09:18:13 EST 2010 | davemacnemo
Machine installer gave me some tips and a run through the software. Everything worked just fine. First solo attempt to run product that we started with gives L305 SoftLimitOver... error after picking first components and passing over camera. Additio
Electronics Forum | Sat Oct 06 15:00:42 EDT 2012 | chrisnims
We bought a used 1999 topaz x and are trying to get it up and running. unfortunately we are getting an error: Anyone know where i can get a service manual or having any idea where to look to resolve this problem? "E229" “Nozzle down limit sensor is
Electronics Forum | Fri Sep 14 02:27:30 EDT 2007 | pavel_murtishev
Good morning, Those random stops are typically related to wrong vacuum limits calibration. Have you calibrated vacuum limits for each nozzle? BR, Pavel
Electronics Forum | Fri Sep 14 02:59:09 EDT 2007 | saab
Out of curiosity, I measured the vacuum levels on our Topaz. With a #31 nozzle the values read somewhere between 130 and 150 when open and about 200 when blocked. The component pickup works fine with no errors with these values
Electronics Forum | Tue Oct 04 05:01:00 EDT 2016 | ok66
Hello! Need help! We have Topaz Xi. Need to place QFP176 (26mm). When optimizing the error E0194 (Component will interfere with other nozzles). Need to turn off one nozzle, don't know how to do it. Сan You help us?
Electronics Forum | Fri Dec 15 11:01:14 EST 2017 | robertorocco
I have one Topaz X FNC machine with this problem. The head 2 FNC not change the nozzle. The head 4-6-8 is ok and change, but head 2 no, when he tries to change the nozzle he gives me an error message. What could be the problem?
Electronics Forum | Fri Apr 24 13:55:09 EDT 2015 | duchoang
- Clean nozzles. - Clean camera. - Adjust lighting. - Check tolerance level. Good luck.
Electronics Forum | Mon Apr 27 07:01:01 EDT 2015 | leeg
Is it failing due to Vaccuum level?
Electronics Forum | Tue Apr 28 01:09:03 EDT 2015 | leeg
Just check that the Vacuum check is on normal and not set to Special Check.