Full Site - : topaz limit error (Page 37 of 49)

Omniflo 5 high temperature warning

Electronics Forum | Thu Sep 04 02:43:09 EDT 2008 | benefon

Thanks This error only occurred with one oven profile with the reflow zone temperature set at 270�C. Perhaps it really has to do with the exhaust pull as the oven is operating very near its temperature limit with this profile. I will check that. Tha

Quad 4c Sequence lead inspection electrical test qa...

Electronics Forum | Tue Mar 12 07:46:26 EDT 2013 | ngineer

bobpan, It only happens with this program. CC ver 7.54, IVC V 3.05 If i leave CC out of it, and edit the sequence using the HHT, it sticks. but if i download from the assembler to CC, it's messed up. if i then fix it in CC, the minute i save

cp743E

Electronics Forum | Mon Mar 25 14:59:55 EDT 2013 | jimmyboz

Yes, he is correct, it is probably a sensor. That does NOT mean a sensor is bad, just that it has not been activated during a time limit or servo count. Watch what the last 2 or 3 things it does before the error.

Pattern matching type fiducial at Topaz/ Emerald machines

Electronics Forum | Mon Mar 26 11:34:31 EDT 2007 | coop

as long as you are not getting recognition errors, and placements look good, go with it. as far as the pattern matching, the only thing I can think of is changing the it from circle or square to sp. shape and giving it the dimension sizes asked for.

Pattern matching type fiducial at Topaz/ Emerald machines

Electronics Forum | Mon Mar 26 11:34:34 EDT 2007 | coop

as long as you are not getting recognition errors, and placements look good, go with it. as far as the pattern matching, the only thing I can think of is changing the it from circle or square to sp. shape and giving it the dimension sizes asked for.

Philips Topaz programming question

Electronics Forum | Mon Aug 06 13:05:19 EDT 2007 | gemengr

Try this... set them on the back and teach their pick up position as stick feeder, change pick up rotation to -90 degree. before you optimize the program, change them to 8mm feeders , them optimize the the program as feeder fix. after the program

Philips Topaz programming question

Electronics Forum | Mon Aug 13 11:24:57 EDT 2007 | jimmyjames

If you're getting that kind of error it's most likely that your feeder bank hasn't been told that the stick feeders can be placed on the back of the machine, or like they said in earlier posts, the stick feeder size itself may be incorrect in the sof

Topaz placement event sequence question (long, rambling)

Electronics Forum | Thu Sep 13 14:18:59 EDT 2007 | slthomas

Just a little status update. When it's running and I monitor the I/O, the mount vacuum bit never turns over to 0. It may be turning over enough to run, but not long enough to see on screen. It stays at 1. When it errors, I can trip it by putting my

Topaz placement event sequence question (long, rambling)

Electronics Forum | Fri Sep 14 10:36:03 EDT 2007 | slthomas

After considerable head scratching yesterday afternoon I've determined that this is a symptom of flaky wiring, a loose connector, etc.. The head 1 mount vacuum bit isn't changing all the time on the blow off, and it errors out at that point. When I r

Floppy formatting for Gemline PPS

Electronics Forum | Wed Jun 19 11:34:37 EDT 2013 | chifutbol

"The disk of B drive has not been formatted as a PCB Data disk." This is the error I'm getting when trying to install lines on a new installation of the Gemline PCB Editor. I have tried using a new floppy, formatted in both opal and topaz machines,


topaz limit error searches for Companies, Equipment, Machines, Suppliers & Information