Electronics Forum | Thu Mar 04 22:52:57 EST 2004 | Roberto Rodriguez
i have a Universal GSM2 machine down and we check all, but are exaust, the problem is the next, when we make Zero axis tha machine say "AXIS HEAD1 Z POSITION ERROR DURING MOVE RELATIVE COMMAND" AND "TIME UP SPINDLES UP". DO YOU HAVE EXPERIENCIES AT T
Electronics Forum | Thu Oct 25 19:53:42 EDT 2012 | sonavc
Thank It worked without the user name and password.When I try to zero axis I have other error unable write to global memory 5008. My machine, when turn it on i don't see the power to the Digiplan 8 axis modular and no bright on 24VAC on at servo co
Electronics Forum | Wed May 04 11:34:17 EDT 2016 | swag
Nice! I always thought of programming as a little bit of facts to get it running then a lot of lies to make it work right.
Electronics Forum | Thu May 19 08:32:46 EDT 2005 | geb
I have a Universal GSM. Does anyone know the maximum width, between the conveyor rails, that a PCB can be. The GSM had an "Axis PWC error", which I think is down to the board width being too wide. This time I was able to halve the board width from 2
Electronics Forum | Tue May 03 10:58:56 EDT 2016 | ttheis
I'm not sure- I'll check that. The machine is running ups version 3.2.2c. Previously I just went into the order list and selected to move the component in the list, put it at the end before the repair step and added an end block step after the compon
Electronics Forum | Fri Jan 27 16:42:29 EST 2023 | dilogic
We have odd problem with zeroing of UIC Advantis (4982B). It performs axis zeroing without complaining (all axes enabled at the end), but after final move of the head to the center of the machine, it hangs without any error message. Status isshowing
Electronics Forum | Tue Mar 14 14:25:15 EST 2006 | geb
Hi, I have a 1995 Universal GSM which won't zero its axis, so can't run. It crashed last night after displaying a "swapper.dat" file being full. I have restarted and checked the available space on the hard-drive - it has over 50% freespace. After st
Electronics Forum | Mon May 02 23:42:44 EDT 2016 | ttheis
I have a strange issue where all 4 spindles of head 1 on my GSM1 are able to place small parts without a problem until the very end of the routine where a large electrolytic aluminum capacitor is placed. The part is successfully picked out of the fee
Electronics Forum | Mon Oct 13 15:33:36 EDT 2014 | rgduval
So...today, we were able to get rid of the z axis not mounted error. It looks like we did so by modifying the settings in axes location (matched them to the beam 1 settings). Now, when we try to lower the nozzles, we can hear a relay or switch clic
Electronics Forum | Tue May 03 10:51:41 EDT 2016 | swag
UIC'S newer software has a category you can change to force a part to the back during optimization for this very reason. I think it's done in placement list. Example: A part coded 1000 will place after a part coded 500. I don't recall what it is