Electronics Forum | Mon Jun 28 09:15:21 EDT 2004 | jdumont
Morning all, we have been seeing some problems with the edges of some of our BGA's curling away from the PCB after reflow. Is this possibly a moisture problem? If so what would be a good time/temp to bake them at to rectify the problem? Thanks in
Electronics Forum | Wed Jun 10 22:47:17 EDT 2009 | davef
You're correct that JEDEC J-STD-033 defines baking condidtions for moisture sensitive components. Why do you want to bake assemblies after cleaning? Search the fine SMTnet Archives for threads like: http://www.smtnet.com/forums/Index.cfm?CFApp=1&Me
Electronics Forum | Wed Jun 24 05:08:37 EDT 2009 | Mark
Try immersing the assembly in IPA for 30 minutes. IPA is hydroscopic ans will drive off most of the water. Dry the assembly. Then bake at 110°C for 2 hours.
Electronics Forum | Tue Jun 09 18:44:20 EDT 2009 | dyoungquist
We are using a water soluble flux which requires the assemblies to be cleaned in an ultra sonic cleaner after assembly. Is there a standard that specifies how long the assemblies need to be baked/dried after being submersed in a water solution for a
Electronics Forum | Fri Jun 26 00:28:43 EDT 2009 | Mark
IPA is hydroscopic.
Electronics Forum | Tue Jun 30 13:20:10 EDT 2009 | charliedci
He wants to "see underwater"
Electronics Forum | Thu Jun 11 10:02:36 EDT 2009 | dyoungquist
Our cleaning process involves the assemblies being completely immersed in the water bath of the ultrasonic cleaner. The assembly has a QFP44 on it. Customer stated that when these assemblies have been cleaned with water in the past (at a different
Electronics Forum | Thu Jun 25 20:01:54 EDT 2009 | davef
Shanelo Technologies Given that isopropyl alcohol [IPA] is produced by combining water and propene. How does soaking a board in water and a flammable liquid drive off water?
Electronics Forum | Wed Jul 01 05:26:31 EDT 2009 | kpm135
But the boards and parts on the boards are also hygroscopic(no not a typo I did a search on hydroscopic and it is not a word the actual word is hygroscopic look it up if you don't believe me) so if you have two hygroscopic materials which one wins?
Electronics Forum | Wed Jun 15 10:38:41 EDT 2016 | laynefelix
Hi everyone..i am new here. I am hardware design engineer and as per my experience PCBAs came out cold soldered after being reflowed the first time with ALPHA WS-820. The flux gel ALPHA WS 609 was supposed to be applied only onto the terminations of