QSP2 Tep Errors

Electronics Forum | Thu Jul 03 09:27:10 EDT 2014 | torch

Hey guys wonder if anyone can help me, having an issue with our Quad QSP2, at the moment it is displaying Tep2 - Send Status command failed Tep1 - Send Status command failed and there is no response from the gantries, the interlocks appear to be wo

SIEMENS S20 Y axis - correct zero pulse not found

Electronics Forum | Mon Jan 28 13:40:53 EST 2019 | liquidspacie

Hello, I'm trying to fix this error and what I've done so far I cleaned (no scratches) measuring scale and swapped cards (gantry 1 & 2) and cleaned scale reader sensor. There are no spare parts, I'm just trding to narrow down the cause. Any suggestio

Siemens SIPLACE HS-60 Errors

Electronics Forum | Fri Jun 26 06:32:33 EDT 2020 | dltechltd

Dear Victor, We have figured out what caused the error: One of it's MVS ICOS card had parity error (The MC reported that error too as seen in the previous pictures). We could see RED LED Light on the card, and we have pulled out, and checked: PAR_ER

Nozzle size

Electronics Forum | Fri Sep 06 13:49:17 EDT 2002 | soupatech

Question: I am going to start placing 3mm x 3mm plastic smt leds and want the absolute lowest errors caused by the nozzle either dropping or allowing the part to shift. Would a 2.5mm nozzle be too big for the 3mm part. My logic is that the more surfa

Siemens S25 X-axis counting error

Electronics Forum | Wed Sep 30 20:35:51 EDT 2020 | erici

Hi all, was wondering if you have any ideas on how to correct the problem we are encountering with our S25 machine. The machine is giving an X-axis counting error at gantry 1. I replaced the x-axis linear reader and the linear scale as well, but st

MPM Ultraprint 2000

Electronics Forum | Tue Mar 28 19:28:54 EDT 2017 | aemery

Giao, These style of MPM's use stepper motors, but no feedback like an encoder or a resolver. In other words all axis positions are assumed after "Reset" of the machine. Because of this style of drive system there is the potential for the vision ga

Camera not parked error on mpm ap 25.

Electronics Forum | Mon Jun 12 23:52:58 EDT 2017 | aemery

Don, either you have a faulty park sensor or much more likely the vision gantry Y axis is not reaching the sensor. Possible issues, one of the two VY drivers cards is failing; one of the VY forcer motors (air bearings) is failing; to much air leakin

Dek 265 GSX motor comms failure ...

Electronics Forum | Thu Sep 22 18:47:08 EDT 2011 | rodrigo

Hi all, We just got this machine and it is not fully functional. I read somewhere here that the folder mint has some useful stuff. I run mint and it said that it cannot communicate with card 0,1,2,3 (x1,x2,x3,x4). It said to make sure the cards are

Component not at nozzle before placement-0402 components

Electronics Forum | Thu Dec 13 10:39:38 EST 2007 | lloyd

Hi Mefunak, I'd say that the vacuum holding circuit is at fault. If the component is picked OK from the feeder ('vacuum check after pickup' is switched on) then the component is being dropped from the head as the gantry moves to the placement positi

First piece PCBA validation

Electronics Forum | Wed May 25 17:56:24 EDT 2011 | rssimmons

The SimmScope is an first article inspection system that uses an overhead digital microsope on a motorized gantry to inspect the board - much like an AOI - except that it does not automatically make the pass/fail decisions. It is up to the operator t


x3 gantry errors searches for Companies, Equipment, Machines, Suppliers & Information

Online Equipment Auction of Altronic: Small-Batch Surface Mount & Assembly Facility

High Precision Fluid Dispensers
Void Free Reflow Soldering

High Throughput Reflow Oven
PCB Handling with CE

World's Best Reflow Oven Customizable for Unique Applications
Baja Bid Auction JUL 9-10, 2024

Stencil Printing 101 Training Course