Electronics Forum | Thu Jun 07 07:31:56 EDT 2007 | jdengler
I was able to get free samples from both Kyzen and Zestron to compare. I would recommend you do the same since your conditions and expectations are unique. Jerry
Electronics Forum | Fri Feb 19 14:53:36 EST 2010 | leemeyer
I beleive that the big difference between the 2 machines is accuracy with the 4C having the better. Nozzles and feeders would be the same.
Electronics Forum | Tue Oct 02 10:26:17 EDT 2012 | jimmyboz
If I had a choice I would choose a CP642 90% of the time. The loading system on the 643 can load 2 PCBs at the same time but is complicated. If 2 seconds on PCB load time is critical on your production choose the 643, if not, choose the 642.
Electronics Forum | Fri Jul 19 04:50:51 EDT 2013 | jlawson
Check out Viscom, X7056 Series in line Xray. Have 2D and 3D options. Also if budget permits offer Xray and AOI in same machine !!!
Electronics Forum | Fri Feb 13 02:03:32 EST 2015 | lambiaki
Hello Can somebody help me? My company would like to buy a new automatic SMT line. Which equipment is better, YAMAHA YS or Europlacer IINEO II. The capacity is same.
Electronics Forum | Tue Dec 11 12:44:34 EST 2012 | deanm
We recently acquired another machine and am faced with the same issue. We are a low volume/high mix company. I chose to run them in series so I can put the more common parts on the first machine and leave them there and put the parts that change from
Electronics Forum | Mon Nov 01 14:44:15 EST 2004 | pjc
Ionograph measures conductivity while the Omegameter measures resistivity. They both accomplish the same task in terms of ionic contamintation detection, but go about it a different way. One is really no more accurate than another. For more informati
Electronics Forum | Fri Jun 23 03:03:47 EDT 2006 | emeto
Hi Russ, I answered with a concrete things. I didn't say "ASK YOUR MANIFACTURER" or "CALL THE TECHNICAL SUPPORT" as the other posts on the same thread. If some of the things I mentioned could help, if the problem is one of them you have the solution
Electronics Forum | Wed Nov 01 07:41:39 EST 2006 | billyd
I'm reworking lead free BGAs now, on a Conceptronics Freedom 3000. I use flux only (no-clean, Indium) all the time, with no issues. If you go to paste, you also understand that you still have to hit the same temperatures as with flux, as the solder i
Electronics Forum | Thu Jun 22 11:39:09 EDT 2006 | russ
So Ev, why did you just respond to a question that you admitted not knowing about? is this not the same? ie... nozzle set error, you know this could be a software conflict error as well? You answered as if it was an inspection error, when I did no