Full Site - : z/156 motor timeout (Page 2 of 3)

MYDATA HYDRA Z/156 error on Hardware Intialization.

Electronics Forum | Tue Mar 03 13:35:29 EST 2020 | emeto

So to sum up: you have no mechanical blockage, you have new motor and encoder. That leaves only two more parts(cable and Hydra Z-Controller).

MYDATA HYDRA Z/156 error on Hardware Intialization.

Electronics Forum | Fri Mar 06 14:33:53 EST 2020 | bk

Another thing you can check is where the bar comes down off of the hydra z motor there is a little bearing you can see from the front make sure that bearing is turning even oil it up a little. You can also adjust the tension by loosening the tiny set

MYDATA HYDRA Z/156 error on Hardware Intialization.

Electronics Forum | Wed Mar 04 12:51:41 EST 2020 | bk

That error means your hydra z did not reach it's specified position. With the machine on you should be able to manually push the hydra down and let it come back up. Make sure it isn't being held up or hitting anything as goes down. Lots of times a pa

MyData error

Electronics Forum | Thu Aug 14 13:49:26 EDT 2014 | dyoungquist

Motor control MSETDYN -> Initiate axis C -> Centering jaws 156 -> Motor timeout Did not reach specified position Hardware problem Looks like you have something wrong with the movement of your centering jaws.

Mydata (TP9-2U) problem

Electronics Forum | Tue May 07 12:30:30 EDT 2013 | shankar2013

We are having a problem with our Mydata TP9-2U where the machine shuts down during a job with this message seen on the service monitor -- F-MOT1-26/156:MOVFI: MOTOR TIMEOUT Has anybody seen this problem?

Mydata (TP9-2U) problem

Electronics Forum | Tue May 07 13:51:51 EDT 2013 | shankar2013

acceleration is set to lowest. Ribbon cables were replaced, theta motor replaced. I also see a message pop up just after F-MOT1-26/156:MOVFI: MOTOR TIMEOUT / F-AXIS-182:C-AXIS NOT properly out when expected / 25v reads 3V. Now all these messages

MYDATA TP9-4 MI board

Electronics Forum | Sat May 29 14:03:18 EDT 2010 | padawanlinuxero

Hello guys! I have a problem I had to change the MI Board on a MYDATA TP9-4 machine because it was firing 3 or more feeders at the same time, after the change it run great but then for some reason after a while it start to show an error message that

Siplace F5

Electronics Forum | Thu Feb 15 20:16:59 EST 2024 | erici

thanks for the reply. The Step motor module at the head is defective, so when the machine does the reference run, it will give a timeout because the DP station and pick and reject stations are not working. I reckon if i disable the RV, maybe i can

Samsung CP 45 NEO, servo motors

Electronics Forum | Fri Mar 22 03:19:43 EDT 2019 | bukas

well, in video shown it looks like #1 motor drives head #1 upwards but does not detect home sensor being triggered. and then you get timeout error, head not being able to reach the position ( machine not registering it has reached position). since yo

Sm t t t net
Previous 1 2 3  

z/156 motor timeout searches for Companies, Equipment, Machines, Suppliers & Information

consignment program

High Precision Fluid Dispensers
Void Free Reflow Soldering

Best Reflow Oven
SMT feeders

World's Best Reflow Oven Customizable for Unique Applications
SMT feeders

We offer SMT Nozzles, feeders and spare parts globally. Find out more


Internet marketing services for manufacturing companies