PCB Libraries, Inc. | https://www.pcblibraries.com/forum/topic2593&OB=ASC.html
. This illustration indicates 3 popular locations for a 0.50 mm dot on an SOP package. The preferred polarity dot placement is at the end of the pad which is the furthest distance from the component package body
PCB Libraries, Inc. | https://www.pcblibraries.com/forum/topic2593&OB=DESC.html
. This illustration indicates 3 popular locations for a 0.50 mm dot on an SOP package. The preferred polarity dot placement is at the end of the pad which is the furthest distance from the component package body
PCB Libraries, Inc. | https://www.pcblibraries.com/Forum/multiple-same-footprint-name_topic797&OB=ASC_page2.html
(x and y) on any device, Lead distance end to end on any device that the leads are larger then the body, bga pad size, DFN pad center to center spacing
PCB Libraries, Inc. | https://www.pcblibraries.com/Forum/topic797&OB=DESC.html
(x and y) on any device, Lead distance end to end on any device that the leads are larger then the body, bga pad size, DFN pad center to center spacing
PCB Libraries, Inc. | https://www.pcblibraries.com/Forum/multiple-same-footprint-name_topic797_post2882.html
(x and y) on any device, Lead distance end to end on any device that the leads are larger then the body, bga pad size, DFN pad center to center spacing
PCB Libraries, Inc. | https://www.pcblibraries.com/Forum/multiple-same-footprint-name_topic797_post2903.html
(x and y) on any device, Lead distance end to end on any device that the leads are larger then the body, bga pad size, DFN pad center to center spacing
PCB Libraries, Inc. | https://www.pcblibraries.com/forum/topic797&OB=DESC.html
(x and y) on any device, Lead distance end to end on any device that the leads are larger then the body, bga pad size, DFN pad center to center spacing
PCB Libraries, Inc. | https://www.pcblibraries.com/forum/multiple-same-footprint-name_topic797&OB=DESC_page1.html
(x and y) on any device, Lead distance end to end on any device that the leads are larger then the body, bga pad size, DFN pad center to center spacing
PCB Libraries, Inc. | https://www.pcblibraries.com/forum/multiple-same-footprint-name_topic797_post2898.html
(x and y) on any device, Lead distance end to end on any device that the leads are larger then the body, bga pad size, DFN pad center to center spacing
| http://www.szhonreal.com/uploadfile/Download/202305231109343783.pdf
±35µm(Cpk≧1) max.112 *2 AC200 ~ 415V *4 . 3-phases 2.2kVA 0.5±0.05MPa max.50L/min 1,800×1,810×1,440 ㎜ 約 1,700kg minimum maximum standard 150mm conveyor extensions, upstream and downstream 250mm conveyor extensions, upstream and downstream 50×50 ㎜ 950×370 ㎜ (double clamping) 360×370 ㎜ 1,200×370 ㎜ (double clamping) 600×370