PCB Libraries, Inc. | https://www.pcblibraries.com/forum/ref-des-text-size-is-not-ok-in-orcad_topic3114.html
. When I convert the footprint into OrCAD, all texts are converted to text blk#3 which has height=1.27mm. For the sake of a test, back in FP designer I changed the assembly text height to 5mm and converted it to OrCAD and again, all the text sizes are stuck to text blk#3
PCB Libraries, Inc. | https://www.pcblibraries.com/forum/topic3114&OB=DESC.html
. In the FP designer, I made a footprint where I have the silkscreen refdes height=1.27mm, and the assembly refdes height=0.5mm. When I convert the footprint into OrCAD, all texts are converted to text blk#3 which has height=1.27mm
PCB Libraries, Inc. | https://www.pcblibraries.com/forum/topic3114&OB=ASC.html
. When I convert the footprint into OrCAD, all texts are converted to text blk#3 which has height=1.27mm. For the sake of a test, back in FP designer I changed the assembly text height to 5mm and converted it to OrCAD and again, all the text sizes are stuck to text blk#3
ORION Industries | http://orionindustries.com/pdfs/gappad.pdf
Gap Pad Themally Conductive Material http://www.bergquistcompany.com/converted/GPVO/GPVO.htm 3/7/00 Gap Pad VO™ Conformable, Thermally Conductive Material for Filling Air Gaps Gap Pad VO is a thermally conductive material that acts as a thermal interface between a heat sink and an electronic device
PCB Libraries, Inc. | https://www.pcblibraries.com/forum/2012-14-released_topic492_post1490.html
) Bug recovering grid array’s with removed pins from converted PLB09 formatted libraries( NA since the converter isn’t released but fixed nonetheless
PCB Libraries, Inc. | https://www.pcblibraries.com/forum/topic492&OB=ASC.html
) Bug recovering grid array’s with removed pins from converted PLB09 formatted libraries( NA since the converter isn’t released but fixed nonetheless
PCB Libraries, Inc. | https://www.pcblibraries.com/forum/topic2190&OB=ASC.html
. The preference values are stored in Micrometers. When a table is loaded the stored values are converted to the selected units for display and when you just switch between them they remain consistent
PCB Libraries, Inc. | https://www.pcblibraries.com/forum/bga-terminal-size-mil-to-mm-rounding_topic2190.html
. The preference values are stored in Micrometers. When a table is loaded the stored values are converted to the selected units for display and when you just switch between them they remain consistent
PCB Libraries, Inc. | https://www.pcblibraries.com/forum/bga-terminal-size-mil-to-mm-rounding_topic2190_post9040.html
. The preference values are stored in Micrometers. When a table is loaded the stored values are converted to the selected units for display and when you just switch between them they remain consistent
PCB Libraries, Inc. | https://www.pcblibraries.com/forum/bga-terminal-size-mil-to-mm-rounding_topic2190_post9043.html
. The preference values are stored in Micrometers. When a table is loaded the stored values are converted to the selected units for display and when you just switch between them they remain consistent