GPD Global | https://www.gpd-global.com/pdf/pbt/PBFT-VS-SPC-User-Guide-20130411-PBT-002P-FORCEWare-v5-6-1.pdf
speed: the pointer should be aligned at: when the stop watch has timed: 100 mm 100 mm 60 seconds 100 mm 100 mm 60 seconds 150 mm 150 mm 120 mm 120 mm 200 mm 100 mm 30 seconds 140 mm 140 mm 250 mm 125 mm 160 mm 160 mm 300 mm 150 mm 180 mm 180 mm 350 mm 175
GPD Global | https://www.gpd-global.com/co_website/pdf/pbt/PBFT-VS-SPC-User-Guide-20130411-PBT-002P-FORCEWare-v5-6-1.pdf
speed: the pointer should be aligned at: when the stop watch has timed: 100 mm 100 mm 60 seconds 100 mm 100 mm 60 seconds 150 mm 150 mm 120 mm 120 mm 200 mm 100 mm 30 seconds 140 mm 140 mm 250 mm 125 mm 160 mm 160 mm 300 mm 150 mm 180 mm 180 mm 350 mm 175
GPD Global | https://www.gpd-global.com/pdf/pbt/PBFT-VS-SPC-User-Guide-20110505-PBT-002N-FORCEWare-v5-5-3.pdf
140 mm 250 mm 125 mm 160 mm 160 mm 300 mm 150 mm 180 mm 180 mm 350 mm 175 mm 200 mm 100 mm 30 seconds 400 mm 100 mm 15 seconds 220 mm 110 mm 450 mm 150 mm 20 seconds 240 mm 120 mm 500 mm 125 mm 15 seconds 260 mm 130 mm 550 mm 110 mm 12 seconds 280 mm
GPD Global | https://www.gpd-global.com/co_website/pdf/pbt/PBFT-VS-SPC-User-Guide-20110505-PBT-002N-FORCEWare-v5-5-3.pdf
140 mm 250 mm 125 mm 160 mm 160 mm 300 mm 150 mm 180 mm 180 mm 350 mm 175 mm 200 mm 100 mm 30 seconds 400 mm 100 mm 15 seconds 220 mm 110 mm 450 mm 150 mm 20 seconds 240 mm 120 mm 500 mm 125 mm 15 seconds 260 mm 130 mm 550 mm 110 mm 12 seconds 280 mm
GPD Global | https://www.gpd-global.com/pdf/pbt/PBFT-VS-SPC-User-Guide-20211209-PBT-002P-FORCEWare-v5-7-0.pdf
VS SPC User Guide 18 GPD Global© Configure & verify calibration procedure 5. Place a load on the strain gauge and allow the weight to stabilize. Note the value of the strain gauge reading. NOTE: A maximum load of 150-200 grams is recommended. 6. Enter
GPD Global | https://www.gpd-global.com/pdf/pbt/PBFT-VS-SPC-User-Guide-20170830-PBT-002P-FORCEWare-v5-7-0.pdf
VS SPC User Guide 18 GPD Global© Configure & Verify Calibration Procedure 5. Place a load on the strain gauge and allow the weight to stabilize. Note the value of the strain gauge reading. NOTE: A maximum load of 150-200 grams is recommended. 6. Enter
GPD Global | https://www.gpd-global.com/pdf/pbt/PBFT-VS-SPC-User-Guide-20210329-PBT-002P-FORCEWare-v5-7-0.pdf
VS SPC User Guide 18 GPD Global© Configure & Verify Calibration Procedure 5. Place a load on the strain gauge and allow the weight to stabilize. Note the value of the strain gauge reading. NOTE: A maximum load of 150-200 grams is recommended. 6. Enter
GPD Global | https://www.gpd-global.com/pdf/pbt/PBFT-VS-SPC-User-Guide-20170519-PBT-002P-FORCEWare-v5-6-3.pdf
PBFT VS SPC User Guide PBFT VS SPC User Guide Version 19.0 May 19, 2017 CE Compliant Part No. PBT-002P for: Model PBFTVS.USB700 for use with: FORCEWare™software, version 5.6.3 prepared by GPD Global
GPD Global | https://www.gpd-global.com/co_website/pdf/pbt/PBFT-VS-SPC-User-Guide-20170830-PBT-002P-FORCEWare-v5-7-0.pdf
VS SPC User Guide 18 GPD Global© Configure & Verify Calibration Procedure 5. Place a load on the strain gauge and allow the weight to stabilize. Note the value of the strain gauge reading. NOTE: A maximum load of 150-200 grams is recommended. 6. Enter
GPD Global | https://www.gpd-global.com/co_website/pdf/pbt/PBFT-VS-SPC-User-Guide-20170519-PBT-002P-FORCEWare-v5-6-3.pdf
PBFT VS SPC User Guide PBFT VS SPC User Guide Version 19.0 May 19, 2017 CE Compliant Part No. PBT-002P for: Model PBFTVS.USB700 for use with: FORCEWare™software, version 5.6.3 prepared by GPD Global
Products, services, training & consulting for the assembly, rework & repair of electronic assemblies. BGA process experts. Manufacturers Rep, Distributor & Service Provider for Seamark/Zhuomao and Shuttle Star BGA Rework Stations.
Training Provider / Manufacturer's Representative / Equipment Dealer / Broker / Auctions / Consultant / Service Provider
1750 Mitchell Ave.
Oroville, CA USA
Phone: (888) 406-2830