GPD Global | https://www.gpd-global.com/co_website/pdf/doc/Advanced-FPC-Real-Time-Controller-User-Guide-22940009.pdf
(i.e. 50 kPa) Process Image DotRunSetpoint=50.0 ASCII Command dtrs=50.0 9/25/20 GPD Global® 29 Advanced FPC Real Time Controller Programming instructions Differences between Dot mode and Continuous mode Dot and Continuous dispense modes differ during the
GPD Global | https://www.gpd-global.com/pdf/doc/FPC-with-Time-Pressure-Control-in-FLOware-Software-22240106.pdf
controller (pg 12) 5 - Standby Standby time-out expires. FPC/TP Monitor (pg 27) 6 - No Run Run is deactivated by operator or Auto- mated Dispense System. Stop controller (pg 12) 3/6/20 GPD Global® 2 FPC with Time Pressure Control - Integrated System
GPD Global | https://www.gpd-global.com/co_website/pdf/doc/FPC-with-Time-Pressure-Control-in-FLOware-Software-22240106.pdf
controller (pg 12) 5 - Standby Standby time-out expires. FPC/TP Monitor (pg 27) 6 - No Run Run is deactivated by operator or Auto- mated Dispense System. Stop controller (pg 12) 3/6/20 GPD Global® 2 FPC with Time Pressure Control - Integrated System
ASYMTEK Products | Nordson Electronics Solutions | https://www.nordson.com/en/divisions/dage/test-types-2020/creep-test
Contact Global HQ Africa Asia Central and South America Europe USA and Canada Nordson DAGE Home Test Types Creep test Creep test glue, visco elastic materials, SMD Time dependent deformation is an
ASYMTEK Products | Nordson Electronics Solutions | https://www.nordson.com/en/divisions/asymtek/your-process/applications-corner/flexible-pcb-meet-flexible-dispensing
? Through dynamic pitch adjustment and the ability to move both dispense valves independently while employing patented real-time skew correction
GPD Global | https://www.gpd-global.com/co_website/pdf/doc/Contour-Mapping-Calibration-User-Guide-221MAPDOC-5.pdf
station. At the same time, however, the area to be mapped should not exceed the servo limits. A total of three glass plate clamps (two side clamps and one top clamp) secure the glass plate, preventing it from moving during the mapping process. NOTE
GPD Global | https://www.gpd-global.com/pdf/doc/Contour-Mapping-Calibration-User-Guide-221MAPDOC-5.pdf
station. At the same time, however, the area to be mapped should not exceed the servo limits. A total of three glass plate clamps (two side clamps and one top clamp) secure the glass plate, preventing it from moving during the mapping process. NOTE
GPD Global | https://www.gpd-global.com/co_website/pdf/doc/FLOwareGEMInterface_1.2.0.pdf
, F16 New Equipment Constant Acknowledge (HE) ......................................................72 7.2.5 S2, F17 Date and Time Request (HE) ...............................................................................72 7.2.6 S2, F18 Date and Time
GPD Global | https://www.gpd-global.com/pdf/doc/FLOwareGEMInterface_1.2.0.pdf
, F16 New Equipment Constant Acknowledge (HE) ......................................................72 7.2.5 S2, F17 Date and Time Request (HE) ...............................................................................72 7.2.6 S2, F18 Date and Time
GPD Global | https://www.gpd-global.com/co_website/pdf/doc/FLOware-Software-Guide-Addendum-Deferred-Reverse.pdf
valve suckback steps. Minimum Shut-off Minimum time (ms) after dispenser stops and before valve shut off is activated.NCM Snap Off Z Distance (mm) to move the valve/tool up during snap off action to prevent tailing. Pinch Delay IN EFFECT AS OF FLOware